Thanks for the reply guys. I cannot get the nozzle angle changed, but only the good thing is saddle are gonna be just used for transport.
As per calculation (Henry H Bednar), the thickness of the saddle comes as acceptable.
Sound like nothing to worry about but still difference in the angle...
My client has asked us to design the saddle for one of their vessel. But due to nozzle arrangement (as shown in the link below, the saddle angle (120 degree) is unequal from both the sides.
i.e. with respect to 180 degrees, I am having 22 degrees + 120 degrees + 38 degrees.
Please help as to...