I have attached an image of what I am trying to model. I have a couple questions. I am trying to model the roadway, which has a bridge parapet. I don't believe there is a straightforward way to set up this type of weir.I could take the openings on both sides of the parapet, and add them together...
Is there any way to customize a culvert opening - to one that is not a conventional round, box, or arch culvert? I could use a customized orifice, but then I wouldn't be able to model the tailwater conditions.
Hi,
I have an existing 6'x6' storm pipe, which I would like to divert a portion of flow from to a proposed detention basin. I would like to place a 14" high x 8" wide weir at invert(136.28') of the existing 6'x6' pipe and place a 12" diversion pipe immediately upstream of the weir - that way...
When I run my model, the blue line at the bottom only goes half way - is this a big problem?
It appears as though my model has completed its run - tehre is water flowing in and out of my basin.
Any info would be helpful. Thanks