    4"-250# Flange Mated with 4"-150# Feasble Technically or Not?

    Thanks all. rneill, Yes, the PRVs (made by Tyco) have CRNs. But unfortunately, the inlet flanges provided are 250# while i got receiver tanks that have been fabricated and hydro'd with 150# flange. CRN's pretty much has been the story of my life for the past year and 1/2 =) Canadieng, A...
  2. Skorp1on

    4"-250# Flange Mated with 4"-150# Feasble Technically or Not?

    thanks rconner. I like the more compact special "Flange Adaptor" solution but I am trying to find one that has CRN (since it will be installed in Alberta Province) and one suitable for pneumatic application. Anyone with information of a supplier that can satisfy the above would be much...
  3. Skorp1on

    4"-250# Flange Mated with 4"-150# Feasble Technically or Not?

    Nevermind, it seems that it doesn't work afterall due to the difference in Bolt Circle...
  4. Skorp1on

    4"-250# Flange Mated with 4"-150# Feasble Technically or Not?

    Hi all, Just have a real quick question: I am nowing dealing with flange rating question concerning SRV (Set Presure at 150 psig) which has 4"-250# inlet connection. But the pressure veseel this SRV is to be mated to happens to have 4"-150# which I believe is not intended. So the quesiton...
  5. Skorp1on

    Max. Temperature Limit (NFC-6 or Table 1B)

    MrBTU - thermal analysis now seems to show mean metal temperature to be less than 300F. yes, it is difficult to imagine tube temperature to exceed 300F but think we have to consider design temperature of shell that is limited by the hot air. unclesyd - tube proper is point contention. Any...
  6. Skorp1on

    Max. Temperature Limit (NFC-6 or Table 1B)

    coolant = water in tube cooled medium = AIR in the shell air tempearture is in the first post. water temp is 30-40 C.
  7. Skorp1on

    Max. Temperature Limit (NFC-6 or Table 1B)

    Thanks MrBTU. However, I am still concerned with what TomBarsh who pointed out that ASME UG-20(c) specifies that "design temperatures for vessels under external pressure shall not exceed the maximum temperatures given on the external pressure charts." I suspect the tube's mean metal temp may...
  8. Skorp1on

    Max. Temperature Limit (NFC-6 or Table 1B)

    how about from non-ASME member?
  9. Skorp1on

    Max. Temperature Limit (NFC-6 or Table 1B)

    I am not a full-time B&PV engineer but I am now faced with a question from someone reviewing a fin-and-tube heat exchanger design that needs to be commissioned quickly. Reviewer is having concern with tube with material SB-111 C12XXX with Design Temperature of 400F exceeding those allowed by...
  10. Skorp1on

    Disconnect Required for 120 Vac (per CSA) for Panel?

    Is there anyone familiar with CSA requirment to provide disconnect switch for control circuit inside NEMA Panel? Basically, I am dealing with a piece of equipment consisting 600 vac for resistance load and 120 vac (step-down from 600 vac) for control circuit. 600 vac feed to high-voltage...
  11. Skorp1on

    Large Part Copper Plating Vendor

    Hi, does anyone have any good recommendations for Copper Plating vendor located in U.S. that can handle large part (100"x 45" x 45") made of aluminum? Thanks.
  12. Skorp1on

    Required Clearance of Live Parts to Grounded Surface inside a NEMA Box

    Thanks pwrengrds - that was helpful. Now to see whether CSA has a similar table. It seems that CSA might be written based on NEC sometimes.
  13. Skorp1on

    Required Clearance of Live Parts to Grounded Surface inside a NEMA Box

    We have vendor supplying a NEMA 4 box for Surge Arrestor/Capictor application and our customer stated that the sidewall clerance is small and may not meet required CSA or IEEE code from live parts to grounded surface. Could you let me know if there is such a requiremetn out there? Especially...
  14. Skorp1on

    Electric Overhead Traveling Crane Welded Box Girder Web Distortion

    Hi everyone, I have a few basic questions as I am currently dealing a web distortion issue found in welded box girder (double overhead running): 1. Is permissible to for butt weld of girder web? In my case, I was told butt-welding is required because bridge span is quite long. 2. Is AWS...

Part and Inventory Search