my apologizes, i made a mistake. please take a look at the attached files. from the attached files you can see that the fillet weld with convex weld profile is with concentrated stress points(stress risers). the weld with concave weld profile, however, has a smoother stress transition. it is...
Single V grove weld can used here because it is possible to finish the weld in 2 passes, which is the same as double V. I am using Rapidarc process (mechanised, forced short arc), to do it in 1 pass. It provides good surface appreance+good welding & metal properties...
Dear all,
Apologise for late reply as i've been busy with some other stuff.
The drawing is from Europe so there's no issue with the symbol (which is opposite with AWS)
The structure is design & constructed according to DIN (supposedly for cranes)
The bevel has been changed to 1mm balance x 45...
JR97,
Thanks for reply.
However, there are some guys said a CJP is needed (not in the forum). This is the part that confused me.
If we leave the question aside, I wonder if a CJP can be achieved? I ask this because of past experience, that a CJP joint can only be produced with a gap set between...
dear all,
thanks for all your kind response!
though i've found a suitable design,grade of concrete and etc... the job has been cancelled. a big blow, but look at the bright side: i've learned a good experience and skills..
(i've even finished the design for the molds).
again, i thank you all...
Dear Ussuri,
Thanks for your advise.
The blocks are used to support ships during works in dry dock,so, they are not submerged for any significant design. However, you've enlightened me about the issue. I will find out more about it.The blocks will only be in the water for a short period of time...
Hi all,
Does anyone here know what kind/type of concrete used for the bow supporting block in dock yard?
If I'm going to use a 1m x 1m x 1m cube block,what type of concrete should I used?
Thanks all!