  1. deepu78

    2 1/4 Cr/Mo P22 materials PWHT temp

    Is there a TTT diagram for A335 P22 material?
  2. deepu78

    2 1/4 Cr/Mo P22 materials PWHT temp

    Our company procedure says PWHT shall meet 730+-15 deg C )for P-5A (2.25Cr-1Mo Base Metal (P-No.) Temperature °F / °C Minimum Hold Time1 (hr) P-5A (2.25Cr-1Mo) 1350 ± 25°F / 730 ± 15°C 2 Our fabricator procured this material and in their PWHT procedure has Holding temperature...
  3. deepu78

    2 1/4 Cr/Mo P22 materials PWHT temp

    Regarding Point 4: Tempering temperature is equivalent to lower critical temperature A1 For SA 335 P22 -lower critical temperature mentioned is 805 deg C . But in the material certificate tempering is done at 740 deg C So can PWHT temperature be above 740 deg C?
  4. deepu78

    2 1/4 Cr/Mo P22 materials PWHT temp

    1. PWHT temp for P22 material -kept at 730+-15 deg C - is this prevent prevent cracking of the weld 2.What is the optimum cooling rate after PWHT 3. Is post heat important for P22 welding 4."After welding, PWHT temperature is kept below the parent material tempering temperature by...
  5. deepu78

    2 1/4 Cr/Mo P22 materials PWHT temp

    P22 Piping materials Tempering process carried out at typically 740degC. Whether PWHT holding temperature for P22 material can be above tempering temperature?
  6. deepu78

    factor of safety-thread794-245390-follow up query

    In the below thread there is a comment The code committee, for various reasons, changed the factor against ultimate from 4 to 3.5 starting with the 1999 Addenda. Factors against yield, time dependent, and compressive did not change. what are the current factors against yield,time dependent and...
  7. deepu78

    Time dependant factors- A106 Grade B pipe

    For SA-106 Grade B pipe ,After 375 deg C the max allowable stress values are time dependant. Notes T1 & G10 ASME sec II Part D NOTES — TIME-DEPENDENT PROPERTIES T1 Allowable stresses for temperatures of 370°C and above are values obtained from time-dependent properties. G10 Upon prolonged...
  8. deepu78

    Derating of process piping designed to ASME B31.3

    Hi Derating of process piping I want to know whether derating can be applied in the below scenario. This is a modification of existing syngas line which is 15 years old. The current piping is designed to 550 deg C and pressure to 52 bar But there is an alarm in the system at 285 deg C. My...
  9. deepu78

    Design Temperature -In service repair /Modification

    NovaStark (Mechanical) How do you de-rate an existing system? What all things to be considered?
  10. deepu78

    Design Temperature -In service repair /Modification

    Operating pressure is same for both temp
  11. deepu78

    Design Temperature -In service repair /Modification

    In what circumstances design temperature of a piping system can be changed? -In a operating plant ,the operating temperature of a particular pipe system (where alteration/Modification required) is max 300 deg C,above which there will be alarm/Trip.But the piping is designed to a higher...
  12. deepu78

    Welded valve replacement to Flanged valve

    The current valve is Pressure seal Parallel slide Gate Valve See below
  13. deepu78

    Isolation Valve Syngas Gate vs BALL

    The current valve is a Pressure seal Parallel slide gate valve see picture below
  14. deepu78

    Isolation Valve Syngas Gate vs BALL

    I have a query regarding Isolation valves in syngas service. Current Valve size is 16"(400NB)class 600 Temperature 293 deg C Pressure 35 Bar Current Valve is a GATE VALVE. What are the pros and cons of using a BALL VAlVE in the place of above GATE VALVE. DV
  15. deepu78

    Welded valve replacement to Flanged valve

    No current plan to install gas detectors on flanges . No existing detectors present for valve stem leak. How important is individual gas detection for these valves? Currently there are gas detectors placed at different location at site and also regular manual check for flanges etc. Also...
  16. deepu78

    Welded valve replacement to Flanged valve

    https://h2tools.org/lessons/ignition-syngas-leak-ammonia-production-plant
  17. deepu78

    Welded valve replacement to Flanged valve

    https://ammoniaknowhow.com/fiorda-case-study-syngas-fire-in-ammonia-plant-compressor-house/