Hi all,
The amplifier I am working with is the Yaskawa SGDH-10DE. It requires 24VDC, 1A (maximum) for the control power. The spec sheet noted that a 24VDC power supply with a double-shielded enclosure is required.
This is probably a very primitive question, but what is a "double-shielded...
Thanks again for everybody's feedback.
The electrics described cannot be re-designed to match more closely to typical industrial standards. The environmenal requirements are set in stone, 20-35 C and 20-80% RH noncondensing. The only flexibility I have is in the design of the enclosure. I do...
Thanks to all your input.
Yes I was quite concerned with the particulate issue. Maybe a fully sealed enclosure with liquid cooling like IRstuff suggested would be a more suitable solution.
Now the dimensions of the enclosure is definitely subject to change. I am aware of the amount of heat load...
Thank you for the reply itsmoked.
I'm sorry for the lack of information in my original post. The chamber will need to be approximately 10"H x 20"W x 25"D. This will house our electronics and leave sufficient space for air flow. The electronics weigh ~55 lbs and require 90-264 Vrms 47-63 Hz, 5.3...
Hi,
I'm not sure if this is the correct forum to ask about this, but here it goes.
For a project that I am currently working on, we have some very sensitive electronics that need to be kept at around 20-35 degrees C and approximately 40% RH (non-condensing) to operate efficiently. I do know...