  1. sdennisf

    corrosion in c02 piping

    Rodney, No moisture. Any moisture would be ice in these systems. Thanks for the links to previous posts. Denny Fegan
  2. sdennisf

    NPSH margin and ANSI/HI 9.6.1

    I'm a mechanical engineer with over 40 years experience, many of those in specifying and applying large, >20,000 horsepower pumps. Your concern over NPSH is a valid one but can be addressed very simply. You must specify that the pump must be stable over its entire operating range without any...
  3. sdennisf

    corrosion in c02 piping

    I have a customer that uses our canned motor pumps in their C02 refrigeration systems between o and +20F. He has asked if we are aware of any corrosion problems in steel or copper piping. I am not aware of any problems but thought I would check to see if anyone has experienced any corrosion...