  1. azahari

    316L Stainless Steel for Plant Air System

    The Plant air header is basically 40mm NB pipe & fittings. Corrosion is mostly from internal. Probably due to the poor performing dryer system over many years. Changing the dryer is out of the question at this stage. Pressure is about 7 bars. I have no real reason to select 316L other than it...
  2. azahari

    316L Stainless Steel for Plant Air System

    Hi All Currently, the plant uses galvanised carbon steel for its plant air system. However, over the years, some part have thinned and had pin hole leaks at several places where we had to bandage it. I am looking to replace the badly affected header section. However, I am trying to see if I...
  3. azahari

    Alternative to 420 Stainless Steel

    Hi Guys. I am new. Be kind please. I am not sure if this is the correct category for the posting. But it is boiler related. The current boiler baffle plate in used at the company site ((Australia) is of 420 Stainless Steel. From the thermography inspections done in the last couple of months...