  1. cher122976

    Best Pipeline Book

    I am a civil engineer and have never been exposed to much in depth water pipeline design. What would be the best book or method to become an expert in this field. I am looking to know all about piping types, fittings, hydraulic design, restraint types and design, backflow and PRV valve design...
  2. cher122976

    Acidity of Rock Backfill

    In my experience that testing is not normally done. You will get a proctor from the quarry but that's it.
  3. cher122976

    Acidity of Rock Backfill

    I was recently asked what provisions are being made for the acidity in rock backfill and it through me for a loop. Anyone have any experience with this? We are designing a 24" steel gas pipeline that will have corrosion protection. In the roadways it will have rock backfill. I think this is a...
  4. cher122976

    Parking Lot Planter Strip Sizing

    That's what I am thinking. It's a gravel parking lot and they are not really needed if not used for plantings. I have seen railroad ties put at ends of rows but dont really understand the usefulness of them.
  5. cher122976

    Parking Lot Planter Strip Sizing

    Is there any criteria for sizing planter strips at the ends of parking isles? We are designing a parking lot and have limited room and want to minimize them as much as possible.
  6. cher122976

    Catch Basins in Gravel Parking Lots

    Does anyone have any experience using catch basins in a gravel parking lot? I have always tried to avoid them due to obvious reason. I think I have seen them used before with a concrete apron around them to avoid dirt and gravel getting in them.
  7. cher122976

    Trenching

    We need to take a 24" pipe under a good size electrical duct bank sitting with a bottom of 5' deep. Is there normally issues with supporting the duct bank during trenching activities?
  8. cher122976

    Concrete pipe trench

    Big inch, you really think a 6'w x 6'd trench is going to float? I don't like the casing idea for multiple pipes at all, too many issues with that. We are going to utilize a concede trench with an removable top.
  9. cher122976

    Concrete Pipe Trenching

    Ron, I think the concrete vault would work well but it will need to have concrete removal lid along the entire length to install the future piping. I dont think that is a big deal to design from a strucural standpoint.
  10. cher122976

    Concrete pipe trench

    Thanks stainier I think the vault is a much cleaner solution then several casings. We do have tresses on site that will also be used.
  11. cher122976

    Concrete pipe trench

    Thanks rakook, I think that would work great. We have one roadway crossing where we will design to H20 but the remainder will have minimal loading. A lot of this trench will be level and there will be some water penetration into the vault so I think 4" drain pipes will probably be necessary at...
  12. cher122976

    Concrete pipe trench

    How would they install the future pipe under the road within the culvert?
  13. cher122976

    Concrete Pipe Trenching

    Is it feasible to even put removable steel plates along 700' of trench?
  14. cher122976

    Concrete Pipe Trenching

    about half the trench is going to be above ground. Rather then a grate I am thinking of just a watertight steel lid along the length of it that can be removed for future installations. But, yes, that is one of the critical design issues I am trying to get figured out.
  15. cher122976

    Concrete Pipe Trenching

    We are designing a concrete pipe trench on an industrial site that will hold 2 24" Gas lines with 2 smaller gas lines running above them. 4 pipes total in concrete trench. One 24" gas line will be laid in the trench initially will the others to be installed with other phases. What would be the...
  16. cher122976

    Concrete pipe trench

    That would be a little extreme dont you think for 2-24", 1-6", and 1-12" pipes? A huge tunnel vs a 8'w x 6'd concrete trench is significant. But, its an option, thakns. I think the road crossings are the most significant part of this design as a grate will work in all other areas. Maybe in...
  17. cher122976

    Concrete pipe trench

    We are designing a concrete pipe trench on an industrial site that will hold 2 24" Gas lines with 2 smaller gas lines running above them. 4 pipes total in concrete trench. One 24" gas line will be laid in the trench initially will the others to be installed with other phases. What would be...
  18. cher122976

    Concrete Vaults

    Thanks. Whats VE?
  19. cher122976

    Concrete Vaults

    I guess what I am asking is what are peoples experience with this. In my little experience with vault design I have prepared a design of the vault with consisted of only a layout (dimensions) of the vault and then specificications for both pre-cast and cast-in-place. These specs gave the...
  20. cher122976

    Concrete Vaults

    cvg, i really dont think as engineers we need to decide on alternatives methods to our entire design up front. Is that what you mean? For vaults, if they design is for pre-cast and they decided to go to cast-in-place who comes up with a rebar and concrete design?