  1. Vinzzzz

    Cathodic protection for plant ping with deep well anode system

    Dear All i have a question about the protection about an underground plant piping system. I have to protect 18 Km of plant piping in a congested area where there is the presence of great aboveground structures like cooling towers and process equipments with concrete foundations. The minimum...
  2. Vinzzzz

    Fitting welding with unequal wall thickness ASME B31.3

    Metengr thanks a lot i don't have seen in figure 1, note 2. Now all isclear. Regards Vincenzo
  3. Vinzzzz

    Fitting welding with unequal wall thickness ASME B31.3

    Dear allI have a question regarding the welding of unequal wall thicknesses for butt welding fittings in accordance to the ASME B31.3. As I have verified for pipes and fittings ASME B31.8 and B31.4 permitt the welding of unequal wall thicknesses only if the max walll thickness is not higher...
  4. Vinzzzz

    Intergranular Corrosion for AISI 316

    dear sirs, thanks for your responses and evaluations. About the possible corrosion mechanisms I want to underline the fact that I don't have Oxygen inside the Reservoir as indicated by Client with associated water analisys. Valve is a GATE type and only trim is in AISI 316 while body is...
  5. Vinzzzz

    Intergranular Corrosion for AISI 316

    Dear all I have had a conversation with one of my client about AISI 316 and it's resistance to pitting corrosion and intergranular attack. My situation is the following, I have selected materials for an Emergency Shout Down valve sited near a well-head where the reservoir is constituted by gas...
  6. Vinzzzz

    Coating on Duplex Underground Pipeline

    Dear Steve, many thanks for your reply. Client have decided for PP coating but anyway I will follow your advice principally for my knowledge. I have another question for you, I have seen on ASTM for Pipe material A790 Grade S31803 that pipes, obviously, shall be fournisced in pickled...
  7. Vinzzzz

    Coating on Duplex Underground Pipeline

    Dear all, is it right to coat an Underground Pipeline in duplesx material type S31803? I'm doing a project in Algeria for a gatering system to construct so the soil is prevalently constituted by sand. I suppose that corrosion mechansms could be done by differencial aeration or electrolites...
  8. Vinzzzz

    Deep Groundbed For Cathodic Protection Systems used for Pipeline prote

    Ok thanks, i have read in an accurate way the peabody book and also Nace RP 572 and now i can say that water is necessary to reduce soil resistivity (as exoplainde from you before) infact during the summer season could be necessary to inroduce water in the well. thanks a lot for your replies...
  9. Vinzzzz

    Deep Groundbed For Cathodic Protection Systems used for Pipeline prote

    ok thanks to all for responses, but let me other 2 questions 1- is real that tipically deep groundbeds are washed in order to decrease the resistivity but i know also (as i understand oon NACE RP 572)that if water goes into the vent pipe, gases developed by anodic reactions could not be vented...
  10. Vinzzzz

    Deep Groundbed For Cathodic Protection Systems used for Pipeline prote

    Hi to all, I'm studing a cathodic protection system done by others, in which is considered the use of an impressed current system with deepwell groundbed with Fe-Si anodes to reach a 100 ohm per metyer. Now constructor say that to a depth of 5 m he have found water and wants to know if is...
  11. Vinzzzz

    what is the difference between API 6D and API 600

    hi a direct question, what is the difference between API 6D and API 600 for gate valves? It is possible, that the only difference is due to the fact that API 6D shall be referred only to Pipeline Valves? If the response is negative, is it possible that one code is more restrictive than the...
  12. Vinzzzz

    Ni Resist or 12% Cr for Pumps Material with brackish water?

    Dear all I have a question about best solution to be done for pumps material selection for brackish water. The total content of clorine ions in the water is about 1660 ppm, PH 7-8, 7000 ppm of CaCO3 and is saturated in oxygen. According to API 610 matertials suitables for water services...
  13. Vinzzzz

    Electro Slag Weld for Internal cladding of Amine Regeneration Columns

    Hi to all, I'm preparing a Data Sheet for an Amine Regeneration Column. As i have studied and known the Amine process is very corrosive principally for two effects : 1- CO2 Corrosion; 2- Second Amine corrosion due to the product formed with CO2 and H2S (if present - in my case i have only...
  14. Vinzzzz

    use of an internal lining in Amine Treatment Flash drums

    Hi to all, I'm still evaluating the use of an internal lining on a Flash Drum used in an amine Treatment Plant. It is to underline that this plant is very small due to the fact that it is a part of a Process Training Plant. I have found a Belzona Product 1391 a Ceramic HT (a two component...
  15. Vinzzzz

    Check valves meaning of "Retainer less design"

    Hi Bernoullies, thanks for your explanation. I have found more info about "retainerless" on web. On API 594 valves droawings are all with the retainers passing through the valve body. Many thanks Vincenzo
  16. Vinzzzz

    Check valves meaning of "Retainer less design"

    hi to all, i have a question regarding Chack valves, what means for a check valve the term "retainer less design"? thanks for all best regards Vincenzo Saviello
  17. Vinzzzz

    Differencies between ASTM A320 L7M and ASTM A320 L7

    Hi Cory, Thanks for your help/explanation i want to attach a good document that i have found on web about Nace Stud Bolts Classes and API requirements in wich it is clear when the L7M or 7M is necessary instead L7 or 7 grades. Nace after 1997 had eliminated the classes and now speaks only...
  18. Vinzzzz

    Differencies between ASTM A320 L7M and ASTM A320 L7

    hi, to all. I'm interested to know if there are differencies between ASTM A320-L7M and L7.I'm selecting bolts and nuts for Low Temp Valves. About their differencies i have found that L7 are mechanically better than L7M and also that L7M are in accordance to NACE requiremnts. Tis means that L7M...
  19. Vinzzzz

    Gunite and Single Pipe system for Sealine

    Hi i'm vincenzo a material engineer and i'm finding systems for two sealines: - the first is 10" - the second 12". I'm Trying to find some insulating system used for sealines as single pipe configuration. I have found also some info about five layer system done by the industry socotherm...
  20. Vinzzzz

    Difference betwen Inconel 625 and 626lcf

    Hi to all, I have a question for materials based on Nikel Alloys. I have to select a nikel alloy to construct bellows (thermal expansion joint) and i found that there are two different type of Inconel 625: - grade 2 as per ASTM A443 (hot worked in sheets; - 626 lcf (worked in special condition...
Back
Top