  1. Paykon

    LCI-2052 Low Current Injector (Mitton)

    Does anyone know where can I rent LCI-2052 Low Current Injector (Mitton) in Canada? My objective is to measure touch and step voltage using the LCI-2052.
  2. Paykon

    Ground water resistivity

    How about to measure water resistivity as a return path for fault current in a hydroelectric dam that uses a penstock or a tunnel for carrying the water.
  3. Paykon

    Ground water resistivity

    If we want to measure ground water resitivity for desiging a ground system for a station what is the procesure? We conducting a ground water resistivity test on the site or take a sample for measuring the resistivity?
  4. Paykon

    Point to point ground impedance test

    One more question. How do we select the selected points for point to point connectivity test in a station to see what points are connected to the grid. If there is no drawing for the grounding system.
  5. Paykon

    Point to point ground impedance test

    Troepe, You are right. We can inject 100A DC current and measure voltage drop and use a shunt resistance to measure current to calculte the resistance of the connection points for point to point connectivity test of the grid.
  6. Paykon

    Point to point ground impedance test

    The link explains about ground grid resistance measurment. I am looking information about the ground-grid integrity measurment test using DC equipmentor high current injection test?
  7. Paykon

    Point to point ground impedance test

    I am looking for procedure of conducting the ground-grid integrity measurment test(Point to point ground impedance test)using DC equipment?
  8. Paykon

    Point to point ground impedance test

    Do you recommend AC equipment or DC equipment for testing and why?
  9. Paykon

    Spillway grounding of hydroelectric dam

    Do you recommend a separate grounding grid design system for the spillway or connect it to the hydroelectric station ground grid? The generator in the hydroelectric dam is connected by a high resistance to the grid and the fault current is limited. But if there is a fault at the line connected...
  10. Paykon

    Spillway grounding of hydroelectric dam

    Hi there, Does anyone have experience on designing gronding for spillway grounding of hydroelectric dam? I would like to have your comments on that? Peter
  11. Paykon

    Step and Touch Voltage measurement procedure?

    Could anybody explain to me where I can find procedure for measuring step and touch potential? Regards Peter