  1. JohnnyHS

    Low Temperature For SWA Cables - Do they exist?!

    Yes a great help Bill - thanks. We have proposed the same to our customer. It is a very small amount of cable we are using, hopefully common sense will prevail. Johnny Johnny H-S BSc(Hons) MInstMC Engineers like to solve problems. If there are no problems handily available, they will create...
  2. JohnnyHS

    Low Temperature For SWA Cables - Do they exist?!

    Thanks Bill, very useful. The situation is that we will be bending and installing in the UK here - ambient 20oC (in fact a little less - you may be familar with our summers!) - not a problem Its for when the system is placed on site where the already installed cable is subjected to -40oC...
  3. JohnnyHS

    Low Temperature For SWA Cables - Do they exist?!

    Hello ladies and gents, Have had a search online and through suppliers for a SWA cable that can operate at -40 to 70oC. i can find non armoured cable that can do this but not armoured. (may just have to conduit/mechanically protect the non armoured) it is required for 230/50 2 Amps. 2.5mm2 3...
  4. JohnnyHS

    Seawater Submerged Borehole Pump (in 8" line) needed for Offshore!

    No steve unfortunately the two offers so far are duplex 2207 & 907L as "standard" - not offering to do a run for 2 off. 6 MO is the sample system standard so good shout for that material but not avail. It seems to be the small duty and the special materials. The lower duty grundfos pump is...
  5. JohnnyHS

    Seawater Submerged Borehole Pump (in 8" line) needed for Offshore!

    Hello lovely Engineering Community! I have an issue regarding a pump that is required for an offshore application (north sea). I'll try and give all the info but keeping it brief to still keep your interest!! Basically it is for supplying sample (5 litres a min required at 5 bar head) to...
  6. JohnnyHS

    Room Pressurisation Continued!

    Ok guys as promised my Heating and Ventilation unit has been tested and the results are in.................. To remind you i needed at least 12 air changes with an overpressure in my room (GRP house) of 50PA. I have an HV unit external to the room which supplies the (sometimes warm depending...
  7. JohnnyHS

    The Prospective Fault Current Clarification!

    Hurrah! I have got my paws on some guidance notes and it states for the prospective fault current(Ipf) section that a) this figure is to be acquired by enquiry or by measurement and b) The maximum prospective fault current recorded should be the greater of either the short circuit current...
  8. JohnnyHS

    The Prospective Fault Current Clarification!

    you get a star for that last post! lol! anyone else?! Johnny H-S BSc(Hons) MInstMC Engineers like to solve problems. If there are no problems handily available, they will create their own problems.
  9. JohnnyHS

    The Prospective Fault Current Clarification!

    thanks you for your reply rbulsara! unfortunately i cannot leave this job for the sparkies! Please have a look at this forum. It looks like they actually measure for the prospective fault current - any comments? In any case could you please tell me the formula for calculating it? In theory i...
  10. JohnnyHS

    Earth Fault Protection relays

    http://blog.sparksdirect.co.uk/rcd-residual-current-device-principle-of-operation-rcd-rccb-rcbo-cbr-srcd/ rather than type out this is what i have found useful. i believe it is rarer to find just a Earth Fault protection relay more likely to have it included in a Residual Current Operated...
  11. JohnnyHS

    The Prospective Fault Current Clarification!

    Hi guys, I’m generating the company forms for the electrical installation certificate schedule of test results to the 17th Edition BS7671:2008 and have the following questions/statements that you fine sparkies may confirm/clarify for me... The Prospective Fault Current This was measured by a...
  12. JohnnyHS

    Coalescer? Water Removal From Hydrocarbon Stream Required.

    Dear All, I am in a bit of a quandary. :-( I need to remove water from a flowing hydrocarbon stream but all the usual suppliers cant seem to do it due to the amount of water and flow rate required from the clean outlet. (Pall, Parker etc) Process: Stabilised Condensate Process Temperature...
  13. JohnnyHS

    Needle Valve Position Pre or Post Flow Meter

    Hi Guys Thanks for your inputs. great stuff! After a little digestion and reading your comments what do you think of putting the Neddle Valve always downstream on the Flowmeter for both liquid and gas. My thinking being this: if the needle valve affects the state (phase) of the medium being...
  14. JohnnyHS

    Needle Valve Position Pre or Post Flow Meter

    Ladies and Gentlemen of the engineering community your input please! I have a flowmeter (variable area) and am deciding where to put the needle valve to regulate the flow for a) the sample line and b) water cooing line. I have had discussions with various engineers with some recommending pre...
  15. JohnnyHS

    AUTOMATIC UPDATE OF THE LOCATION OF AN AutoCAD FILE

    hmmm that sounds plausible! Thanks for answering IFRs how do i do that?! ie what would i type in the template file? I am just looking to have the file location within the template Thanks :-) Johnny H-S BSc(Hons) MInstMC Engineers like to solve problems. If there are no problems handily...
  16. JohnnyHS

    AUTOMATIC UPDATE OF THE LOCATION OF AN AutoCAD FILE

    Hello you beautiful helpful people. May be (hopefully!) a really quick question here. I would like to have a file location field inserted in my title block (initial template with company and rev numbers etc on it used for all new dwgs) so that when that template is used in a project and filed...
  17. JohnnyHS

    Electrical Heat Trace Circuit Breaker Choice

    BINGO! (and who doesnt love BINGO!) http://www.toolstation.com/shop/Electrical/Circuit+Protection/GE+RCBO+10A+30mA+Type+C/d190/sd2615/p17137 http://www.hbo.com/larrydavid/episode/season5/episode44.html :-) Johnny H-S BSc(Hons) MInstMC Engineers like to solve problems. If there are no...
  18. JohnnyHS

    Electrical Heat Trace Circuit Breaker Choice

    Kiribanda, Thanks for your help. in particular you have opened my eyes to the actual function of the ELCB. I thought that it did the overload protection AND earth leakage. I was wrong and your last post made me investigate further.. Fellow Viewers...
  19. JohnnyHS

    Electrical Heat Trace Circuit Breaker Choice

    ok thanks for the replies guys. bit more information. 1) The system is going into a Romanian Refinery. The specifications as to what is acceptable is very vague from the client but we are under obligations to supply a functioning safe system under our (UK) specifications (statute and good...
  20. JohnnyHS

    Electrical Heat Trace Circuit Breaker Choice

    Good Morning All! you guys are usually so helpful so i'd thought i'd put this little poser for you electricals to lap up. Am sure this is bread and butter for y'all but for a mechanical process guy its made me think twice as well as a few guys around here and i would like to consult your...