Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations IDS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: DudePipeliner
  • Order by date
  1. DudePipeliner

    What is two-pack epoxy?

    Can you simply explain to me what does the "Immersion-grade two-pack epoxy" means? what does two-pack means here? Pipeliner Dude Offshore Pipeline Engineer
  2. DudePipeliner

    anode design: concerete coating thickness difference

    How much is the maximum allowable difference between concrete coating and anode thickness? I heard about some 25mm as maximum...is it allowed? Pipeliner Dude Offshore Pipeline Engineer
  3. DudePipeliner

    Piggability Criteria

    I asked a question about pipeline pigging which it seems misunderstood! I know that the ID is finally important matter for pigging, but I don't know which items shall be accounted for? lets say that the pipeline has two sections with 14.3mm and 15.9mm wall thickness. so is the ID difference...
  4. DudePipeliner

    Piggability: Internal Diameter Deviation Criterion?

    To make pipeline piggable, the internal diameter shall be somehow unique along the pipeline. the deviation , as I know, up to some 5% is acceptable for conventional pigs, while 2% is recommended for Intelligent ones. the question is how the deviation shall be calculated? which parameters shall...
  5. DudePipeliner

    DnV RP F103 vs. DnV RP B401: Coating Breakdown factor

    Thanks Steve, It seems that's the best option. Pipeliner Dude Offshore Pipeline Engineer
  6. DudePipeliner

    DnV RP F103 vs. DnV RP B401: Coating Breakdown factor

    Yes Steve, I know about the scopes and you are right. however, I mean the difference between previous B401 (1993) which was also applicable for pipelines and the new F103 (2003). does the large difference between breakdown factors is related to improvements in Coating quality? I found a document...
  7. DudePipeliner

    Coating breakdown: DnV RP F103 vs. DnV RP B401

    the coating breakdown coefficients (a and b) in DnV-RP-B401 where in order of 0.1 and 0.01. these coefficient are remained unchanged in new revision of B401. on the other hand, the DnV-RP-F103 proposes very different coefficients, which are in order of 0.001 and 0.0001; which leads to very light...
  8. DudePipeliner

    DnV RP F103 vs. DnV RP B401: Coating Breakdown factor

    the coating breakdown coefficients (a and b) in DnV-RP-B401 where in order of 0.1 and 0.01. these coefficient are remained unchanged in new revision of B401. on the other hand, the DnV-RP-F103 proposes very different coefficients, which are in order of 0.001 and 0.0001; which leads to very light...

Part and Inventory Search