  1. grady

    normalizing of 6061 T6 Al after welding

    I have been told that by exceeding a welding temperature of 250-300 degrees F, that I have normalize the 6061 T6 AL, thus causing it to become very ductile....I.E. rockwell hardness of around 35. any suggestions would be appreciated. I have called out a 1/8" fillet weld...I suppose an...