Hi Pipeline Dude,
Piggability criteria starts with ID of the pipe.
Typically if it's mechanical pig (caliper pig), the disc size/OD is 95% of pipe ID. Therefore, use the smaller ID with 95% of pipe ID for disc OD.
If you are thinking of foam pigs, typically foam pig is OK for any two API pipe...