  1. juanon

    Allowable Bending Stresses for A325 Bolts

    Dear All, I have a situation where on removal of a blind flange on the vessel accsess hole it was observed that the stud ( 3/4-10UNC-2A)was bent approximately 1/16" ( measure at the tip of 5 1/8" long stud). Further review suggested that the the access hole stud holes got skewed. The...
  2. juanon

    Alteration in Bolt holes of 3-1/2" Blind Class 900 raised faceflange

    Hi A class 3-1/2" 900 RF Blind flange has some interference when mounted on the boiler opening due to misalignment of the stud holes. This is due to incorrect drilling of the stud holes on the boiler face at an angle which has a few bent studs installed ( off by 1/16"). While...
  3. juanon

    Magnetic drive sealless internal gear0 vs Rotary external gear pump

    Gents, Thanks for your help Pumping manual 9th edition TC Dickenson provides nice comparison. Lochie, I also believe the same; we are looking at the maintenance records to get a feel for the recurrence of the problem. thanks for your input
  4. juanon

    Magnetic drive sealless internal gear0 vs Rotary external gear pump

    Friends, We are doing an evaluation on replacement of Rotary external gear pump with mechanical seals with a magnetic drive sealless internal gear pump. The application is for Lubricating Oil recirculation ( continuous duty): Flowrate of 26USGPM , Pressure of 25 psig Temperature of 43.3 deg...
  5. juanon

    Carbon steel and Stainless Steel interface issues

    Can any body guide me to articles dealing with interface issues with stainless steel and carbon steel fittings ? Any help would be much appreciated. Regards
  6. juanon

    Recommendation and sizing basis for Footvalve/strainer on a gear pump

    Pardal, sorry to be late in responding. I appreciate your help. It is obvious you are talking real life experience. To summarize your thoughtful email. a) STRAINER Let the suction be as free as possible : Avoid any restrictive device at the inlet. In fact, their is a provision at the...
  7. juanon

    Recommendation and sizing basis for Footvalve/strainer on a gear pump

    Pardal, FYI Flow to handle: 26USGPM Kind of oil:Lube Oil(superturbolfo 32) It´s specific weight:0.87 sepecific viscosity:33.4 Tank temperature:40 deg c mean size of the particulate to be filtered:30-50 micron Thanks
  8. juanon

    Recommendation and sizing basis for Footvalve/strainer on a gear pump

    Friends, I have a rotary gear pump for lube oil pumping having a negative suction lift of 20". A strainer /footvalve arrangement is proposed a the suction to remove particulates and maintain the suction line primed. Do you recommend this configuration ? If so any design guidelines (...