  1. puckman31

    motor storage

    I have become incharge of spare motors and such. What shouid i know or learn how to treat spare motors that are part of sub pumps , i am talking aout 40hp and larger motors . I have read on here about heaters in motors ,where to get information with that would help. Guess there installed at a...
  2. puckman31

    vfd app.

    the slip ring i used is a rotating electric connection to a 460v motor. I can not explain this any better and hope most people know what i mean. thank you for you patience.
  3. puckman31

    vfd app.

    Are there many problems using a vfd on a 460v 1 hp inverter duty motor that uses a slipring ?. Are there some concerns with this design ?. A good part of the work by motor is at 60 hz
  4. puckman31

    diesl gen for electric mcc

    the reason i ask is we have 1500 kw gen they run about 1 hr a week without a load and were told that it could lead to wet stacking which is not good. don't know if this is true.
  5. puckman31

    diesl gen for electric mcc

    can a diesl gen runa without a load without doing any damage ?
  6. puckman31

    compressor

    I told everything i know about the air line and was trying to find out about correcting this setup. by using a little knowledge the line 200' long without anyway of releasing the condensation has to be a bad setup. there are actuators and solenoids on the header. the header does not have a way...
  7. puckman31

    compressor

    We have two compressors with dryers auto drains and then the air line goes out for 200' out in the plant. Should there be some type of drains out in the plant where the air just waits to be used up. we have equipment that locks up and no one knows way. does condensation come in to play here...
  8. puckman31

    Test pump packing

    thanks for all the responses and help
  9. puckman31

    Test pump packing

    I am looking for a test method for packing a pump that would indicate there is a problem before it is installed. Thank you to all who respond.
  10. puckman31

    Test pump packing

    Is there a method to test a pump that uses packing for a seal when on the bench and no motor attahed? This is so the pump is not installed and then find out that it is leaking way to much when operated.
  11. puckman31

    air compressor

    whats the best way to supply compressed air to air actuators ? Piping = black iron, stainless , aluminum , pvc ? what do i have to do to keep the acuators clean and clear of water dirt etc ? gages, filters ? Thanks for any help .
  12. puckman31

    pump damage?

    We have a system, hot water circulating through 4" lines with 4 pumps with 10hp motors . Only 1 motor / pump working at a time. The hot water is circulating through all the pumps even thoug they are not running . Is this a bad design for the non running pumps because when the water passes...
  13. puckman31

    torque switch?

    It is a 5 hp and I want the lower amp end of the motor that is chain drive . Thanks to everyone for their help.
  14. puckman31

    torque switch?

    I am looking for a device i can use on my gear motor i can use to shut down the motor when it is working at a higher or more powerful rate. A shear pin is not working at this time, any ideas?
  15. puckman31

    solar power

    Thanks irstuff for trying. I should have added the "solar energy is off to the main breaker".
  16. puckman31

    solar power

    A question was asked one day that when the main circuit breaker is off is the solar energy off? Also we have a system that says it has multibile power sources coming into our main panel, my answer was yes it is off. Does anyone disagree ? We have roof pv panels , no batteries, and it is suppose...
  17. puckman31

    480v motor

    Cjhut, sounds like good advice and infomation . Thanks
  18. puckman31

    480v motor

    I want to thank the person for his reply to my post, but I think he was assumming a little to much. I ask an opinion on a subject that I don't that much about [ pm on motors ]. Please be assured that i am an electrician. Thanks for your reply
  19. puckman31

    NFPA 20 and UL listed

    national fire protection agency 20 . all i can tell you is for pumps , fire pump installations. and if there is anything else to it i am not sure.
  20. puckman31

    480v motor

    I left some stuff out of my last post I ment to ask about. In some pm's they ask about voltage on lines 1, line, 2 line 3, does anyone think that is the best way or would l-1 to l-2 than l-1 to l-3 and l-2 to l-3? IS there a size of motor in hp where you would start with pm's?