  • Users: HiSet
  • Order by date
  1. HiSet

    Power outage in Ecuador

    Thanks for the update and do you know if it was a mechanical failure of the tower/line or failure of the protection scheme?
  2. HiSet

    Power outage in Ecuador

    Does anyone know what caused wide spread power outage in Ecuador yesterday?
  3. HiSet

    CT response to DC current

    Recently numerical Trf Diff relay of an out of service transformer picked up when it’s HV dead tank circuit breaker was being tested for contact resistance by injecting 200A of DC current.I am bit curious to find out CT behaviour or response to pure DC current. Please share your views
  4. HiSet

    Accuracy of Px class CT

    Is there a way to find/derive the accuracy class of protection class CT with following specs ? Ratio- 1000/1A, 0.1 Px 500 R 3.0 ohm Is it fair to say that such a CT will equivalent to metering CT of class 1 accuracy?
  5. HiSet

    Does anyone know what caused the po

    Does anyone know what caused the power outage in Argentina and Uruguay?
  6. HiSet

    Voltage selection relay

    we have an application wherein under voltage load shedding scheme needs to select 3 phase voltage from one of possile three line VTs.Can some one suggest a voltage selection relay capable of accepting three sets of three phase voltages?
  7. HiSet

    Fault Limiter

    Does anyone have experience with ABB make fault current limiter called "Is" ?
  8. HiSet

    Under Frequency Load Shedding scheme

    Phonanian and Slavag, Thanks for for use full tip.I would love to read IEEE document on this subject recommended by Slavag but can't get into IEEE website.Can some one upload this document on this website please?
  9. HiSet

    Under Frequency Load Shedding scheme

    Guys, Thanks for you valuable responses.UFLS scheme in question is part of state wide system protection scheme and consists of various stages consisting of rocof and simple under frequency stages.On tripping side it trips mix of residential and industrial loads at appropriate frequency...
  10. HiSet

    Under Frequency Load Shedding scheme

    What criterion should be followed for designing Under frequency load shedding scheme i.e. should it be based on security i.e.by having contact of main and check relays in series to issue trip or should it be based towards reliability or dependability i.e. by having contact of main and check...
  11. HiSet

    IEC 61850

    Slavag Well I beg to differ with your view point on this issue.IEC 61850 is (or will become) very much part and parcel of protection as it talks about how to send CBF or interlocking signals via GSSE/GOOSE or how to send sample values from CT and VTs, both conventional and non conventional...
  12. HiSet

    IEC 61850

    Is there a forum to discuss protection issues related to IEC 61850 standard?
  13. HiSet

    Switch Fuse unit

    David, Thanks for that.Your last option seems most prudent but how do you make sure that busbar is physically isolated after genuine bus fault. All other circuits(CBs) will trip by virtue of trip signal emanating from Bus prot scheme but station service bay will remain connected and...
  14. HiSet

    Connecting a wind power station to existing net (GRID)

    Attached document produced by ESB, will give you some ideahttp://files.engineering.com/getfile.aspx?folder=c99392ce-c4bf-4ee7-b3a5-eaed5925b9cd&file=Review_of_Draft_Wind_Power_Station_Grid_Code_Provisions.pdf
  15. HiSet

    Switch Fuse unit

    It is about busbar proptection of HV(22kV) board ,where all circuits except station service transformer circuit have dedicated CTs for high impedance based bus protection scheme. Station service trf bay is switch fuse unit without CT. Appropriate fuse can be choosen to make sure that BZ scheme...
  16. HiSet

    Switch Fuse unit

    Is it possible to trip switch fuse unit via external trip signal? In other word does HV (22kv)switch fuse unit have trip coil?
  17. HiSet

    Software to draw electrical drawings

    Which is a good and easy software package for drawing electrical schematic drawings pertaining electrical power system ?
  18. HiSet

    Transformer Tapping Methods

    I would like to know difference,advantages and disadvantages of having transformer tap changer based on variable flux and constant flux method?
  19. HiSet

    Florida Outage Preliminary report

    Does anyone know as to what level of financial penalty was imposed by the regulator for this incidence?
  20. HiSet

    132/33kV Trafo vector group - Dy or Yd

    PRC, One of the ways to reduce fault current of YY grounded transformers could be by specifing high positive and zero seq impedance.