Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. MeltLabGuy

    Graphite Flotation

    Carbon flotation in ductile iron is caused when the foundry allows the Carbon Equilivant to exceed the ability of the magnesium to suppress graphite formation in the liquid. My experience suggests that limit is about 4.55 - 4.60 with moderate levels of magnesium 0.030 to 0.035%. Spectrometers...
Back
Top