Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. krugtech

    Bystronic Bystar 3015 4.4kw

    anti clockwise Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  2. krugtech

    Bystronic Bystar 3015 4.4kw

    What was the actual pressure when you started the turbine? If the pressure is too high or if you tried to start the turbine before it vacuumed down, you will have this problem. The turbine should only be run between ~60 and ~140 Kpa Are your 3 laser gasses correct? if you have N2 or CO2 where...
  3. krugtech

    Bystronic Bystar 3015 4.4kw

    Rana- you can use another vfd, like a delta C2000 but you'll have to configure it. If the vfd is outputting 370hz, the rpm will be correct. You can find those connectors in the schematic, there's a reset signal, a run signal, and a 120hz signal to break in the bearings. If the blower is...
  4. krugtech

    Bystronic Bystar 3015 4.4kw

    Darren- Are the fans running on your chiller? Rana- what VFD did yo have originally and what resonator do you want to use it in? Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  5. krugtech

    Issue with Bystronic BL 1500 Laser Software CNC-90 ver. K4825A DOSbox 0.74

    You have to hit shiftlock and F1 while in the menu that shows the drives at the top of the screen and reconfigure the drive list. I have a lot of CNC90/dosbox experience. Feel free to call or txt 706-627-7854 Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  6. krugtech

    bystronic 3015

    Whe was the last time someone gave the machine a tuneup? Hows the output power? Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  7. krugtech

    HI We have a bystronic bystar 3015

    Removing the tube between the output window and shutter usually resets it. They want to see that someone took the tube out to look at the optic. Call or txt me 706-627-7854 for help. Did you look at the actual temperature of the optics while cutting? Chris Krug http://krugtech.com/ Maximum...
  8. krugtech

    Bystronic Byspeed 3015: error E29

    It could be a leak, a weak vacuum pump or a combination of both. Does it happen more often in fastmix? Feel free to call or txt for help 706-627-7854 Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  9. krugtech

    Bystronic mmc problem

    reinstall mmc and I hope you have a good "save everything" Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  10. krugtech

    Bystronic Byspeed Error E98

    the laser control signal and the can bus are both common to the byvision cnc rack itself. That's where I would start. Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  11. krugtech

    ByStar 2512

    Watch the motor shaft on the z axis, does it move smoothly while it's cutting or is it jumping? It's either a sensing issue or the bearings in the z axis Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  12. krugtech

    need independent mitsu laser tech in Georgia USA

    I like working on bystronic, I need an independent mitsu tech for a friend w a fiber laser. thanks Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  13. krugtech

    Bystronic laser

    did you reset the circuit breaker? it's probably a shorted traswi, transformer or rectifier, possibly one leg of the 3 phase is missing. troubleshooting this is deadly if you don't know the rules. other than that it's simple. first step is inspect hv for arcing and burnt spots. don't let that...
  14. krugtech

    thread380-484800 BackMetalService d

    thread380-484800 BackMetalService do you still have that linux image? Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  15. krugtech

    Bystronic Handling Problem

    I think you got a stuck key. it could be the extended keyboard too. disconnect the standard keyboard first, ten the machine keyboard, they're hooked up via PS2, USB or serial. hook up a standard usb keyboard via USB to test. Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  16. krugtech

    Bystronic Handling Problem

    The link is an heic file, what do I do with that? Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  17. krugtech

    Bystronic laser problem on chiller

    do you have a bypos, and are you getting bypos errors on the CNC? Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  18. krugtech

    Bystar 3015 - Stuck on "Vacuum Pump Running" during Startup

    I'd smack it lightly with a hammer. :) A smart guy told me it fixes them. Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  19. krugtech

    Higher wattage laser or waterjet for 1/4" aluminum?

    Have you considered a waterjet/plasma combo? tcicutting.com makes one and it's getting a lot of attention. Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS
  20. krugtech

    Fiber laser

    I'm with IRstuff, especially the safety aspect. That light is very dangerous compared to CO2. Chris Krug http://krugtech.com/ Maximum Up-time, Minimum BS