  1. IndianTechEngg1001

    Type of MCB to be used inside the EX e street Lighting Junction box

    These MSBs are normally used in equipments panels (for like chargers/ UPS/ Electronic/ Telecommunucation systems) where it is not always poessible t provice e/i enclosures on them. If someone wants to use these MCB inside a protected enclosure then also these is no problem. But even if a normal...
  2. IndianTechEngg1001

    Why Reactor named as Reactor?

    Reactor is an inductive device then why it is called a Reactor?
  3. IndianTechEngg1001

    Substation Reactors Standards

    Can anybody help in finding codes numbers for Shunt Reactors, Neutral Earthing Reactors, Tuning Reactors, Smoothing Reactors, Load Balancing Reactors and Interphase Reactors for US and Europe Use?
  4. IndianTechEngg1001

    Battery Sizing

    As per IEEE STD 485, K factor are to be taken from the cell performance curves. As per attached image please advise if value of k be less than 1 for loads of duration less than 1 min (like for 20 sec loads). I have worked out some battery calculations for a substation and if I take 1 minute...
  5. IndianTechEngg1001

    Shunt Reactor at the start and the end of Transmission Line

    How to find the ratings of shunt reactor MVAr at the end and the start of transmission line? Help needed. Thanks in advance.
  6. IndianTechEngg1001

    Transmission Line- Thermal Limit vs short circuit current

    I go it,, thanks everybody. Just one more clarification. When we select high tension cables we see the short circuit current while selecting the cable size. Like if current is I=22kA then size of Al cable will be S=I/K where k=0.094. So cable to be selected is > 235sqmm (say 300sqmm)/ We...
  7. IndianTechEngg1001

    Transmission Line- Thermal Limit vs short circuit current

    For 220kV line, the thermal limits are normally 300-1000MVA with economic power 350MVA. If I calculate current using formula P=1.732 x V x I (P= Thermal Limit=1000MVA) I=2624A Is this my short circuit limit for breaker installed for this transmission line operation/protection? Thanks in advance.
  8. IndianTechEngg1001

    Load Flow Cases: Overload %

    I am involved into load flow studies for a system with Generator, Transformers and Transmission lines. I am referring a book "overhead power lines, Planning Design , Construction" by F. Kiessling, P. Nefzger, J F Nalasco and U Kaintzyk) I am taking following cases. In book following cases are...
  9. IndianTechEngg1001

    PLS-CADD

    What is your purpose of using the software? Like points plotting, Sag calculations, Tower Design, Vegetation Management etc. If this known then we can put more words here.
  10. IndianTechEngg1001

    Air Gapping Electrical

    I am also with Mr. Scotty. I have also seen that while doing any maintenance people believe what they see. Air gaped between contacts is something which people can trust for safe working. I have seen people preferring breakers with fuses over MCCB as that can takeout the fuses and put them in...
  11. IndianTechEngg1001

    Auxiliary grounding/ earthing for Isolators in substation.

    I add all into following....please check 1. Auxiliary ground Grid should be bonded to Ground Grid where Grid connects the switch lever ground strap. 2. The purpose of this auxiliary ground is to keep potential of handle lever and ground at persons atep at same level. 3. Size 1200mmx 1200mm...
  12. IndianTechEngg1001

    Software for Substation Layouts

    I was searching a software which can assist engineers in making the layouts of substations. I know one from Bentley (Bentley Substation). Is there any other software you aware of?
  13. IndianTechEngg1001

    Auxiliary grounding/ earthing for Isolators in substation.

    Any idea from where this size 1200x1200 with conductor spacing 300 came from? OR it is just a practice everybody following up?
  14. IndianTechEngg1001

    Auxiliary grounding/ earthing for Isolators in substation.

    Yes it is the one where operator will stand. He is telling me that normally he saw following for grounding/earthing Normally For 400kV Switch Yard- Mesh Formed is LxW :: 1500mmX 1500mm spacing of rod @300mm this was beneath the isolator Normally For 220kV Switch Yard Mesh Formed is LxW ...
  15. IndianTechEngg1001

    Auxiliary grounding/ earthing for Isolators in substation.

    One of my friend asked me this question where he was wondering if a separate earthing design is done for isolators 220kV. These grounding/earthing are then connected to main grid. If it is done what practices are followed? He was calling this earthing as auxiliary grounding/ earthing. If...
  16. IndianTechEngg1001

    Voltage econimics in selection of Substation Voltage

    I know one formula Economic Voltage = 5.5 Sqrt{L/1.6 + KVA/150} Where L = Length of Transmission Line KVA is Power to be transferred Is anybody aware of the standard/ code from where this taken? Are there other methods also to check the voltage economics?