  1. longzul

    VS4 Sump Pump vibration

    Thanks for your reply guys. Pump spec is: Sulzer TAN1130 Capacity: 12 m3/hr speed: 2900 rpm Head: 32m NPSHr: 1.3m Power: 2.2kw length from base to bottom: 4.7m sump pit length: 6m impeller type: enclosed impeller diameter: 178mm pump mounted on rectangular base plate Pump is actually used for...
  2. longzul

    VS4 Sump Pump vibration

    Hye experts, Need your advise. Currently in my plant we have VS4 type pumps for waste water treatment. The pumps used to pump out the sludge from the pit. We use double arrangement bearing at the coupling side and carbon bushing at each pipe support in order to minimize vibration. The problem...
  3. longzul

    cannot unfold part and sheet metal

    hello..can somebody help me..i try to make 2 half cylinders connected together like a L shape..the problem is that ive tried to unfold the structure but i cant..first i was using .catpart and try to unfold using drafting but it said the encumbrancy of the selected solid is null. and then i tries...