Hope someone can help
In NX7.5 (Manufacturing - Turning) you are able to measure a distance using using the IPW
This does not appear to work in NX9 and cannot find the preference setting to do this in NX9
Nothing is highlighted when hovering over IPW
Screenshot is using one of the NX7.5...
Problem occurs trying to add an angular dimension in drafting
Horizontal dimension has been added using a tangent point and end point
Have tried to create angular dimension using horizontal dimension as one object and angle edge as second object
Error message is raised and dimension is not...
When I look at part file history I would normally expect to see messages like this under Program column
Part renamed from
STEP203TOUG
Refile Part
Could anyone explain what this type of message is
NX 8.5.3.3<!<AP203PKG>!>
Currently using NX8.5.3.3
Is it possible to have the "Sketch Name" dialogue box displayed in Direct Sketch
Using the Sketch Task Environment there is a dialogue box displayed where the sketch name can be set to give the sketch a more meaningful name
The only way I can see to change the name of...
Running on Windows 7 I can start NX6 and NX7.5 okay
When I try to start NX8.5 or NX9 I get NX Initialization Error (See attached screen shot)
The message says to check the Java Runtime Environment variable buts does not state which one or what it could be set to
Can anyone offer any guidance...
In NX8.5 when I try to use the "Assembly Load Options" not all of the menu options are there
I can only see "Part Versions" and "Scope"
There is no button to expand the menu
Missing is "Load Behavior" "Reference Sets" "Bookmark Restore Options" "Saved Load Options"
What do I need to set/select...
Hello All
When creating a turning geometry the spun profile is created correctly for workpiece and blank
Looking in the Part Navigator the Spun Outline, Dayum Plane and Mirror body are in Feature Group along with the orginal features
To help tidy up the Part Navigator you can right click and...
I have defined a turning tool and saved to the tool library
Tool has been defined on the X-Y plane
When I call this tool into CAM the tool appears in the correct orientation and
loads onto the turret in the correct position
Adding an NC operation I get the attached error message