i have to design a combined footing which can take care of 30,000 lbs uplift for a carport. its not difficult to design it in case when i have moment and uplift/downward force acting on the foundation.
but in this case i need to put piles in the foundation. piles will take care of the downward...
we ordered Square bolts and the supplier sent out the U bolts. Installers did not notice about this. and started putting on the U bolts. Now there is a gap between the bottom of U bolt and the tube. How can i overcome this problem?
I have a project for solar systems racks. I placed an order for Squared bolts but for some reason they delivered the U bolts to the site and most of them have been installed. I cant change the order now. I need to know if there is any way that I can use the U bolts as Square bolts to hold a...
@msquared48
thats what I did in the beginning. I used a method from my text book elastic beams on elastic soils. But the client didnt approve of it and he wanted design of pile on a commercially accepted software. I used com624,apile and lpile to satisfy him.
I went to the site and most of...
@a2mfk
my company has already done a similar project before but the guy who designed it before is gone.
The problem was that client didnt want to use any concrete in the foundation. the other solution was to provide large size of pile since the soil was weak and distance from ground level to...
Thanks a lot for the advices.
@BAretired
i recommended the same thing in my office but they dont want to get into all another connection design of piles.
@msquared48
That was the first thought came to my mind, putting the pile in a caisson. But client needs results out of LPILE and I want...
I have been assigned a task to design H Pile foundation for a solar company. The Maximum size i can go with is JIS 150x100(5.85"x3.94") because of the connection problem with the solar system.
If i use 150 x100 then using LPILE the deflection i get is 3.5" app. The minimum section that...
hi
i am going to install temporary shoring for Rte 405 and for this project i need to put some plastic sheathing all around the perimeter of soldier beam so that slurry doesnt stick with it when i remove the beams.
do you know what kind of plastic material should i use for that?
im currently working on route 405 project and we need to build temporary shoring. i have asked a lot of companies but no one seems to have MC 18x 58 sections to be used as walers for tiebacks. can i use W 18x46 section which has almost the same section modulus if i dont find MC 18x58? or else...