  1. JonnyZ

    LTS Glycol injection plant turndown

    This particular design is as you say run as a two-phase separator followed by heating then liquid-liquid separation. Still i'm surprised that liquid-liquid separation occurs when done in a cold 3-phase LTS separator, similar mixtures exist in gas reception facilities for instance were glycol is...
  2. JonnyZ

    LTS Glycol injection plant turndown

    Re the observations on HTFS i also notice it predicts a whopping 3x increase in pressure drop with glycol. You may think thats overinjection - i've set the rate to give 2 to 3wt% average dilution of the glycol to ensure operations are maintained in the safe concentration region. On a slightly...
  3. JonnyZ

    LTS Glycol injection plant turndown

    Thanks maddocks, you’ve obviously got a lot of good experience in this area. To follow up on some of your advice... Tube plugging is certainly an option available for planned shutdowns . Not sure on its usefulness in this instance as the production profile is relatively rapid ascent and...
  4. JonnyZ

    LTS Glycol injection plant turndown

    I'm looking for some guidance on designing MEG glycol injected gas-gas exchangers for gas turndown on an LTS, say 5 to 1. Minimum tube gas velocities of 12-15ft/s are recommended in thread124-70137 and elsewhere to provide good dispersion through the tubes. The turndown of these exchangers is...