  • Users: KVVS
  • Order by date
  1. KVVS

    Outlet line size of PRV

    I am fully agreed with poli60. me too never see such thing in my past projects. I already put note regarding out let size. thanks everyone .
  2. KVVS

    Outlet line size of PRV

    Thanks for reply
  3. KVVS

    Outlet line size of PRV

    Dear Sir, During review the P&ID, I saw PRV out let line size is less than inlet line size. is it possible ? PRV having 4.5 barg set pressure & connected with LP flare header. I understand inlet line size & outlet line size govern by different factors like but usually outlet line size is greater...
  4. KVVS

    Valves on the inlet of a PSV

    As far as normal engineering practices valve should not put at inlet of PSV, but if it is required for maintnance purpose than put Locked open valve. now come to the question , as per my observation valve should have full port same as nominal dia of pipe.
  5. KVVS

    Check Valve In Relief Valve Discharge Line

    yes dear........i am fully agreed with zdas04.
  6. KVVS

    Two inlets for a PSV

    thanks someguy79
  7. KVVS

    Two inlets for a PSV

    Thanks chance17 for reply.........dear my PSV placed on heat exchanger discharge line so there is no internals ........but as you say one line size out of two exactly equal to the PSV size. kindly tell me there is any specific requirement to put such type pSV.
  8. KVVS

    Two inlets for a PSV

    Hi every one during P&ID checking , I saw several place two inlets provided for single PSV. it gave me little surprise . can any one explain the purpose of the same. thanx in advane.
  9. KVVS

    High point vent required at mdea solution pump discharge

    Hi all I have to check isometrics of CO2 removal section. during checking of aMDEA solution pump discharge line isometric , i found out a high point vent is provided. i little surprised to see the same . can be apply this normal practice in aMDEA solution too. please help me. thanks in advance
  10. KVVS

    velocity criteria for PSV suction line

    right sir, there is any guideline regarding velocity criteria for inlet PSV line. Some where i read that 70% of sonic velocity can treat as for same. can i take this for all time ? please help me. thanks in advance
  11. KVVS

    velocity criteria for PSV suction line

    Dear All, there is any guideline regarding velocity criteria for PSV suction . thanks in advance
  12. KVVS

    PSV sizing for different case

    dear sir, i want to know PSV sizing for two cases, first one for fire case and second for tube rupture in heat exchange. sir please give me guidence in this regard. thanks in advance,
  13. KVVS

    shell type selection

    dear , type of exchanger depend upon which type fluid is used. to study this you may refer TEMA or LUDWIG volume-3.
  14. KVVS

    PSV sizing for different case

    dear sir, i am new in this field. i want to know about PSV sizing for different case. plaese help me in this regard. thanks in advance