  1. niteshgargeck

    Tube plugging

    I hope guy who invented wheel shud also have patented it. I was not asking for whole document just wasted to hav knowledge of particular topic. But i appreciate efforts put by respected members
  2. niteshgargeck

    how to protect the PTFE vlave packing and B/B gasket from damage during post weld heat treatment.

    if you are going to do stress relieving then most probabely it will be low alloy steel valve. in low alloy steel high pressure valve always ask vendor to give graphite packing not ptfe because on your working temperature it will fail for sure. and yes while doing pwht temperature will go more...
  3. niteshgargeck

    Torque Value

    You can refer the standard torque values as per the bolt size moc n type of coating/finish.
  4. niteshgargeck

    API Trim 10 instead of Trim 12

    There should not be any big concern by using trim 12. the difference between both is only in trim 12 seat is stellite. now the thing is where the difference lies. yes with stellite you can have some problem because in practices, hard-facing of seat through stellite can negatively affect the...
  5. niteshgargeck

    Stratagy for Preventive Maintenance (Valve)

    There are no standard guideline which generally being followed for valve Pm in process industry. Also it depends on the type of valve. If it is a mechanically operated valve means valve with handle generally greasing is done whenever you get the opportunity. In case of control valves which are...
  6. niteshgargeck

    reason of PSV pop up agaisnt the set value

    there can be several reason of it. if psv outlet was connected to any header so may be because of increased back pressure itz popping up on highr pressure. pop up pressure decided by spring force. check your maintenance history,was any adjustment done with spring in past. is there any cdsp...
  7. niteshgargeck

    Tube plugging

    thnx Aconnell
  8. niteshgargeck

    Tube plugging

    hey Aconnell i do not have copy of tht standard. can you upload it for me,
  9. niteshgargeck

    Tube plugging

    @r6155 in tema they did not mention anything about puncturing the tube.
  10. niteshgargeck

    Tube plugging

    thanks cristine but i m looking for some code or firm reference on same subject.
  11. niteshgargeck

    Tube plugging

    Its a FD type gas fired boiler. tube is in economizer panel.
  12. niteshgargeck

    Seal Selection for CFG Pump on Slurry Duty

    I would suggest to use stuffing box packing with lantran ring with grease holes or a water ring. Mech seal will be very expensive because you will have to select an outside flushing fluid in sealing plan.
  13. niteshgargeck

    Tube plugging

    Hello My question is there any standard or reference which gives exact guideline that whether we have to puncher a tube before plugging. This is the case of boiler where we have leak in a bend. now can i remove the bend and plug the tube or i have to puncher the tube then plug it.
  14. niteshgargeck

    Tube plugging

    Can anybody tell is there any standard which define whether we have to puncher the tube before plugging.
  15. niteshgargeck

    sleeve bearings

    It is always less then your bearing metal temperature.