Thank you all!
Basically my problem is this:
In a project we are finishing right now,the penstock diameter is 4500m. We measured the roundness of the pipes, 4 measures in total to know the OUT OF ROUNDNESS, and it must comply with this:
Dmax - Dmin <= 45mm (1%) - based on ASME VIII UG-80...
For Penstocks: Can the hydrostatic test be susbstituted by 100% UT inspection on all welded joints?
Or the hydrostatic pressure test is mandatory?
thanks
Good afternoon
We´re starting a steel penstock installation in Panama with this features:
Material: ASTM A-506 gr70
Plate thickness: 1"
Penstock Diameter: 5m
Lenght: 300m
Which codes should I follow for this installation?
Does ASME B31.1 Power piping covers this application?
Does ASME...