  1. Chanda

    Scrubber capacity

    It is not clear whether you are looking for a packed scrubber or something else. Also, whether you are using phase-separation only (as mucour suggests) or other process, maybe absorption or chemical reaction with absorption. I have done reasonable work on packed scrubbers with absorption and...
  2. Chanda

    Best Diameter of Pipe

    As a thumb-rule, vapor velocities are limited to 30 m/s and keeping the dP less than 0.113 bar/ 100 m. Also, liquid velocities are limited to 3 m/s but to 1.5 m/s for corrosive services. The above are general guidelines and should be evaluated for the case considered. For 2-phase flows, erosion...