This is a constant subject of confusion API 6D defines a Double Block and Bleed Ball valve as a valve with SPE (single piston effect) seats on both sides of the Ball these are designed to self relieve. You can also have DIB - 1. & DIB - 2 which are double isolation and bleed valves. The former...