  1. wisnu11

    Vibration on tank due to air floatation

    We have an API 650 tank of 8m diameter and 9m heigh which is equipped with internal pipe running on the bottom of the tank with holes and flowing air as means for mixing the fluid in the tank. well it's actually a means to prevent excessive sedimentation on the bottom o f the tank since the...
  2. wisnu11

    Telltale hole for Roof Opening repad

    Thank you Duwe6
  3. wisnu11

    Telltale hole for Roof Opening repad

    Duwe6 Agree with you. One last question. if no telltale holes provided (which mean we can not do soap test), should a simple PT to examine the weld of the repad be sufficient?
  4. wisnu11

    Telltale hole for Roof Opening repad

    JStephen Thank you, however I've found many tanks where the roof nozzle repad is full seal welded and yet no telltale hole is provided. or if rephrase, if we decide to seal weld the repad of the roof nozzle (repad to the roof plate and repad to the nozzle neck), does API 650 suggest to add a...
  5. wisnu11

    Telltale hole for Roof Opening repad

    I was wondering why in API 650 paragraph 5.8.4 and 5.8.5 do not mention the requirement of telltale hole for the roof opening repad, either manhole or nozzle. In the Shell opening section (para. 5.7.1 to 5.7.6) it is clearly mentioned for this requirement. However in paragraph F.7.3 (point 3.)...