Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. MATe10

    Steam Injection Line MI Thermocouple Failure

    It was enclosed in another 316SS capillary tube, however it appears to have been breached and some of the reservoir fluid and steam entered. SAGD(Steam Assisted Gravity Drainage) is a method of obtaining bitumen from oil sands by injecting steam into a well and collecting the heating bitumen.
  2. MATe10

    Steam Injection Line MI Thermocouple Failure

    Hello All, I have a 1/8" diameter 316 SS sheathed magnesium oxide insulted thermocouple that was placed inside a steam injection well for a SAGD operation that has failed. It was subject to ~240C temps and 1400kPa pressures and also inadvertently exposed to around 10ppm chlorides and 51 ppm...
  3. MATe10

    Welding P-7 materials to P-3, P-4, P-5A, P-1

    Does anyone have any experience welding these combinations? I was thinking ER309L but it seems like a preheat of 300F would make this filler flow way too much. ERNiCrMo-3 would give me an unacceptable hardness, I think. Any sugestions? THANKS