Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Apexpredetor

  1. Apexpredetor

    Slab on Grade for Modular/Mobile Home Installation

    I regularly design cookie cutter foundations (frost protected, full basement, block, poured, etc...), but I have been asked to design a simple slab on grade pad for a Double Wide home installation. I can't really convince myself that a simple 6" pad with Welded Wire Fabric (WWF) will suffice...
  2. Apexpredetor

    Am I reading Code Incorrectly?

    Good Evening All, Quick question about Residential Code, Section %502.5(2) - Girder Spans and Header Spans For Interior Bearing Walls... Since I have a good depression on the side of my house I was thinking about making a garage under a prefab cape code type addition... I am looking at some...
  3. Apexpredetor

    NYS SWPPP Question

    peter... If I claim that the grading/terracing along with vegetative barriers to runoff, along with check dams in road culverts (if we even call them culverts, they will just be small depression along road between lots) could be used as green infrastructure, correct? Thanks again for the guidance.
  4. Apexpredetor

    NYS SWPPP Question

    No development services department, just a planning board, that will use another local engineer to review the documents for approvals and comment. I used TR-55 NRCS program to model the pre and post development conditions. It is a 14ac site, but only about 1.65 acres of impervious area...
  5. Apexpredetor

    NYS SWPPP Question

    Sorry for the duplicate post here... I was recommended to move it to this forum... Thanks in advance for any info and opinion. I have been asked by a family member to help them with, what appears to be, a fairly simple SWPPP/SEQR permit. He/She is expanding upon an existing Mobile Home...
  6. Apexpredetor

    water hammer

    Valve timing. Use a self closing valve and slow down the time in takes to completely shut the valve. Only "slam" it closed in an emergency. You can hydraulic, mechanical, or air accuated automatic valves readily.
  7. Apexpredetor

    NYS SWPPP Question

    I have been asked by a family member to help them with, what appears to be, a fairly simple SWPPP/SEQR permit. He/She is expanding upon an existing Mobile Home Community. The expanded area is on slope, but will be terraced to properly build pads for the manufactured homes. there will only be...
  8. Apexpredetor

    Looking to Use Steel Beam in Residential application

    YEs. Sorry for teh confusion. I didn't intend to splict the beam, rather I wanted to know if anything special was needed to join them at the column supporting the ends of each. I was assuming some sort of splice plate to keep them together longitudinally, but nothing that will be considered a...
  9. Apexpredetor

    Looking to Use Steel Beam in Residential application

    Excavation costs are nothing bug fuel for me (HAve access to excavator and heavy equipment). I have a mason lined up for CMU or concrete pour (all of his labor free due to giving him free rent at my 80x60 pole barn, and I grew up with him). Only reason I'm trying to get as big as I can is...
  10. Apexpredetor

    Wood Column size and prescriptive Code

    NDS.. ahhhh Totally slipped to look there. I was thinking that it must have been outlined in the Residential code that I was blinded.
  11. Apexpredetor

    Looking to Use Steel Beam in Residential application

    You are correct. I looked at engineered I joists and I have found some that will be clear span at 28ft but for second floor use. If I decide not to make this only 28ft or decide to go heavier loading I think that the engineered floor trusses won't work or might get very expensive at such close...
  12. Apexpredetor

    Looking to Use Steel Beam in Residential application

    Sorry for the confusion... 1) "I am a NY PE, not a home owner." then "I am designing a structure for MY OWN RESIDENCE" ? I typically mention that I am a PE, not just a homeowner looking for a quick answer on here. I say this to let any potential responder know that they should not shy from...
  13. Apexpredetor

    Looking to Use Steel Beam in Residential application

    Sorry to confuse. If I went with the hollow core they would be clear span modules. I was just responding to SU10's comment on the concrete floor
  14. Apexpredetor

    Looking to Use Steel Beam in Residential application

    When I say connecting them longitudinally I am referring to a long narrow type structure of greater than 40ft. I am thinking my structure will be approx 28ft x 48ft. I am thinking that I am not going to get a beam over 40ft in length (or get one shipped very cost effective) so I would have two...
  15. Apexpredetor

    Looking to Use Steel Beam in Residential application

    I will most likely be doing my own design because I really don't think that the steel will provide much in advantage and I will probably go with LVL and I joists, but I am now curious to the applications and designs of this scenario with steel beam. I'm stumped on how to connect the beams...

Part and Inventory Search