  1. ENGRANIA

    Can i use commercial brass CU200 in

    Dear cheristine74 , Thanks for your help
  2. ENGRANIA

    Can i use commercial brass CU200 in

    TEMA CLASS R , I have a big no. Off commercial brass plates CU 200 with very good price. I want to purchase them. As usual our company uses Copper for baffles. What i want to know if commercial brass as a material with all his properities is accepted to use in baffles. If yes , what is the temp...
  3. ENGRANIA

    Can i use commercial brass CU200 in

    Explicit !!!! Please , if you have a certain questioner , you can ask me directly
  4. ENGRANIA

    Can i use commercial brass CU200 in

    Can i use commercial brass CU200 in manufacturing baffles of heat exchanger. What is the temp. Limit and restrictions???
  5. ENGRANIA

    If there is any restrictions or lim

    It is required to replace the old firetube A-106gr. B WITH PIPE API 5L (IN STOCK ) as a material for firetube for heater treater (vessels that contain liquids produced from wellheads. Heat is introduced to the liquids through the use of a natural gas or hydrocarbon liquid burner that is mounted...
  6. ENGRANIA

    If there is any restrictions or lim

    It is required to replace the old firetube A-106gr. B WITH PIPE API 5L (IN STOCK ) as a material for firetube for heater treater (vessels that contain liquids produced from wellheads. Heat is introduced to the liquids through the use of a natural gas or hydrocarbon liquid burner that is mounted...
  7. ENGRANIA

    What is the partial pressure limit

    Natural gas air cooler
  8. ENGRANIA

    What is the partial pressure limit

    Partial pressure 1.14 psi
  9. ENGRANIA

    What is the partial pressure limit

    NACE 0175, as i want to use sa-179 hic material in gas cooler with 1000ppm at 275°f.
  10. ENGRANIA

    What is the partial pressure limit

    What is the partial pressure limit of wet H2S for carbon steel at what temperature
  11. ENGRANIA

    Recently, the gas process component

    I know that duplex s.steel will be better but Galvanic corrosion can occur where different metals are coupled in a conductive fluid. So i prefer using SA-179 but i have some doubts about its behaviour with wet H2S.
  12. ENGRANIA

    Recently, the gas process component

    Sorry , i don't know that my thread will appear in all forumes so i share it indvidually.
  13. ENGRANIA

    Recently, the gas process component

    Recently, the gas process component has large change in some harmful component specially h2s which reaches to 1000 ppm. Now we want to replace the existing bundle for gas air cooler by new one. The existing material for the old bundle is Tubes sa- 214 Tube sheets, plug plates and end platez sa-...
  14. ENGRANIA

    Recently, the gas process component

    Recently, the gas process component has large change in some harmful component specially h2s which reaches to 1000 ppm. Now we want to replace the existing bundle for gas air cooler by new one. The existing material for the old bundle is Tubes sa- 214 Tube sheets, plug plates and end platez...
  15. ENGRANIA

    The manufacterer of the stripper ov

    @ MJCronin Thank you...