Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by kkoca

  1. kkoca

    Tolerance for pipe to nozzle mating

    Hi everyone, Many thanks for your useful comments and suggestions. - Artisi, these values are based on the datasheets. I'll check the exact dimensions of the pump inlet/outlet and flow meter tomorrow after dismantling the old piping system. - LittleInch, OD values are based on the datasheet...
  2. kkoca

    Tolerance for pipe to nozzle mating

    Artisi - thank you for your response. Would it then make sense to enlarge the pipe ending to 100 mm to ease alignment? Because I have the same problem (97.4 mm to 100 mm) just before the flow meter (DN100-ID).
  3. kkoca

    Tolerance for pipe to nozzle mating

    Thank you for your responses - greatly appreciated! Yes, I forgot to mention... There are some flanges in between. I don't currently have all details with me, but have tried to summarize in the following sketch and hope it helps:
  4. kkoca

    Tolerance for pipe to nozzle mating

    Hello everyone, I'm new here and appreciate your advice on the following issue: What would be the mating tolerance between the suction/discharge pipe size and the pump's inlet nozzle? In my case, I'll pump water with a single-stage volute casing pump (Qmax = 72 m3/h). The inner diameter of the...