Dear georgeverghese,
Thanks for the suggestion.
Currently, there is no problem however, sometimes i am facing some running conditions which i cannot explain. for example, in our facility (oil producer) we have a centrifugal compressor for natural gas injection (4 stages producing 350 BARG)...
I am looking for a good book explaining the Centrifugal Compressors (Theory, calculations, operation, maintenance, etc).
i am not a designer however, in many occasions i need to calculate some important parameters such as shaft power, polytropic efficiency, discharge pressure,..
I need advice...
In our water injection facility; BB5 multistage pump is installed; every time only NDE mechanical seal fails. DE is okay. any specific reason?
this pump is equipped with 53B mechanical seal piping.
I am expecting some reverse pressure from pump discharge while pump is not running (may be the...
Dear bimr,
Thanks for your reply.
For diaphragm condition. visually it is good. May be some aging is causing the problem.
What about the diaphragm clamping area? I would say, it may cause the problem also. what do you think?
Thanks
Reciprocating pump LEWA. diaphragm is sandwich type, means two PTFE diaphragms in between an intermediate fluid.
problem: Diaphragm rapture pressure transmitter alarm!
dismantled the pump, diaphragm found in good condition.
what could be the other reasons.
what is function of the intermediate...
Our GE Frame 5 gas turbine; the starting system consists of fixed speed induction motor with hydraulic torque converter (twin disc make/ single stage).
How the machine is accelerating from firing speed (20%) to self sustain speed(60%)?? The starter motor is fixed speed and the torque converter...
Thanks Hoxton for your reply.
herewith I have attached the drawing for better understanding.
In some manuals it is mentioned; the purpose of the quill shaft drive is to absorb the axial movement of both units. still this is not clear for me.
also cannot figure out how the quill shaft is...
In Frame-5 Gas Turbine, Load gearbox is equipped with a single quill shaft drive. it is a FLENDRGRAFF gearbox.
I need to understand, what is the advantage of quill shaft power transmission? why cannot we use a normal parallel gear unit?
also could not under stand how the quill shaft is connected...
I hope some expertise to explain me about the difference between the axial and vertical split case multi stage pumps.
what is the design differences? applications, pressure ranges..
which design should have a balance drum/disk? and which one is equipped with leak off sleeve?
what is the...
In gas compressor; what is the specific heat ration? How could it affect the compressor performance?
in compressor's data sheet; I can see Cp/Cv varying with the temperature. is this the only parameter which could affect it?
thanks
Dear LittleInch,
Thanks for your reply.
Yes. I can do this. however still I need to understand; during normal conditions (seals are ok), should we see any air coming from these openings?
Please note that, this unit still under commissioning! it is recently installed.
Regards