Apologies for your time.
The dimensions and conditions of one of the Production Slug catcher (3x50%) are as follows:
Vessel: Horinzontal
Size: 4900mm ID x 19600mm T/T
Design Press: 3500 kPag
PSV Set Press: 3500 kPag
HHLL: 4000mm
Discharge Location: Hp Flare Header
As explained earlier the...
Thanks for the response.
There is a control valve on the outlet vapour line and an ESD valve both on the outlet liquid line and on the feed line.
I was guessing the feed ESD valve will trip after the ESD valve on the outlet liquid line trips.
What do you think?
Hi everyone.
For a blocked outlet on a production slug catcher I need to determine what my releif load through the PSV when discharge lines are blocked. Do i size the PSV based on vapour rate or based on liquid rate?
For a Blocked Outlet API states that (a) For Liquid, capacity is maximum...