Recent content by Samingme755

  1. Samingme755

    Pressure drop for heat exchangers

    hi, can anyone give me the deference between total pressure drop and the allowable pressure drop for heat exchangers? thanks in advance
  2. Samingme755

    diesel fire water pumps

    hi for diesel fire water pump diesel engine shall be designed for designed for continuous operation or not in other way does the diesel pump need to be suitable for Open valve start-up considering that pump is for Emergency Fire pump application. thanks in advance
  3. Samingme755

    Anti reverse rotation arrangement

    Hi our pump vendor propose that Anti reverse rotation arrangement cannot be provided due to limitations of manufacturing for fire water pumps electrical and diesel pumps and i am asking if its normal thanks really appreciate the help
  4. Samingme755

    corroded heat exchangers

    the contractor provides this sentence in the engineering drawing of hot oil exchanger and I'm wondering if it is standards to do that for new project thanks
  5. Samingme755

    corroded heat exchangers

    hi i want to ask about the procedures for Corroded heat exchangers hydrostatic test for engineering new heat exchanger for new plant thanks
  6. Samingme755

    DIAPHRAGM PUMP

    HI i need help regarding diaphragm pumps without external flexible coupling i want to know whats the problems that coming with this type of pump regarding maintenance and exploitation thank you
  7. Samingme755

    BEARING HOUSING IN DUCTILE IRON

    HI FOR LIQUIDE RING VACCUM IM ASKING OF THE DEFFERENCE BETWEEN STEEL BEARING HOUSING AND DUCTIL IRON AND FROM PASR EXPERIENCES WHAT ARE THE PROBLEMS THAT COME WITH DUCTILE IRON HOUSING THANKS IN ADVANCE
  8. Samingme755

    BENDED PIPE

    HI Littleinch i mean in the process of formalizing document for new complex is it important to mention the bent pipe minimum center line as your previous experience in engineering documentation for new complex by the the document title is GENERAL SPECIFICATION - LAYOUT AND PIPING DESIGN CRITERIA...
  9. Samingme755

    BENDED PIPE

    HI Bent pipe shall have a minimum center line radius not less than 5 times the nominal pipe size. is this sentence need to be added in document PIPING DESIGN ARRANGEMENT CRITERIA in other words, what's the importance of this and what is the requirements for radius center line bases on previous...
  10. Samingme755

    Asme B16.47 series A and B

    Hi In new project instalation which best to select between flange b16.47 series a and series b ? And wich usual application for flange series a Thanks in advance
  11. Samingme755

    BEARINGS TYPE FOR BB3 PUMPS

    hi im asking about the selection of bearing for bb3 pumps and whats standards do i need to follow to chose between sleeve bearings and ball type bearings thanks
  12. Samingme755

    PIG LAUNCHER/RECIEVER

    thanks littleinch much appreciate
  13. Samingme755

    PIG LAUNCHER/RECIEVER

    HI For the design of pig station launcher and recovery for new line, I want to install a smart pig after years for now it's used for dumb pig my question is weather pig launcher and receiver can be suitable for smart pig or I need to modify thanks a lot
  14. Samingme755

    fire water pump

    hi im asking for fire water pump whats the best api material class to imply location is near the sea thanks