    PSV Set Pressure

    As per ASME SEC VIII DIV.1 UG-125 (C), there is no upper limit but the mimimum set pr. is MAWP+10% OR MAWP+3 psi, Which ever is greater. for more detail, refer Code Book. subhen praharaj
  2. subhen73

    Dished head

    MP or LP is must required as per ASME depends on the MOC subhen praharaj