ASME B31.3 also states that slip on flanges can be used where severe erosion, crevice corrosion is expected and for toxic, flammable services as well if double welded.
Hi,
Is it technically a bad option to go for SS EFW pipes for all sizes from 15NB and higher. I've referred few Pipe material Specifications where Seamless pipes are used upto 200NB and above 200NB they're generally EFW pipes. Is it possible to 100% radiograph small size EFW pipes for SS and...
Hi,
What is a stronger connection between Half Coupling and a Stub in for branching of a pipe?
For Stub in we get a butt weld connection which is stronger in branch as opposed to 2 welds in half coupling? Why do we still use half coupling as we have to anyways make a hole in the run pipe in...
1503-44,
I'm using weld neck for normal fluid services now. Just for cooling water, Potable water, Nitrogen, Fire water I'll be using Slip on flanges. Slip on flanges are generally from 50NB to 600NB in sizes.
How about CS and socket welded fittings?
We are using CS for caustic lye, alcohol and phthalates with design conditions below 200 degree Celsius and 6 bar.
Would it cause problems if we use CS socket welded fittings as well?
TugboatEng,
Thanks. I will check the flash point and take preventive measures. I will also check other normal fluid service that are operating above flash point and make sure the I avoid socket welded fittings.
GD2,r6155
Hot Oil service will also be normal fluid category, I mentioned it separately because it has the highest design temperature with the fluids I'm working. All other fluids have at the most around 100 to 150 degree Celsius operating temperature and 6 bar pressure.Even with such low...
LittleInch, TugboatEng,
Thanks for your reply, I'm leaning towards using weld neck flanges for 50NB and higher sizes for process lines and slip on flanges for utilities like cooling water. For 15Nb to 25NB, socket welded flanges seems my only option.
Thanks TugboatEng and LittleInch for the reply.
I will be using socket welded fittings and flanges for 15NB to 40NB for CS and SS as well and for Hot oil service will use Butt welded fittings and casted flanged valves to avoid bottom out issues. Hopefully, I'll be able to convince my client.