i used the formula of B31.3 for 1/6 thickness and internal pressure but data sheet is different i do not why used max pressure 226 psi for 1" and thk=0.133
max allowable stress in table A1=20ksi amd table A1-M=138 or 137.9mpa
following used for which code ?
p=2s×e×t / ((D-2×y×t)×sf)
sf between...
hi
i used eq : p=2se(t-c)/d-2×y(t-c) to calc max pressure for A106-B seamless at temp 100F
Od=1.315 , t=0.133"-12.5% s=137.9mpa
Result=26.3mpa or 263bar
but i visited some websites and got following formula with safety factor ( while b31.3 not mentioned safety factor just states basic...
FootNote Table 323.3.5 :
👉 (2) Energy values in this Table are for standard size specimens. For subsize specimens, these values shall be multiplied by the ratio of the
actual specimen width to that of a full-size specimen, 10 mm (0.394 in.).
please help me to understand note2
Note 2 : (min energy for subsize) = it says min energy for standard_size depend on tensile × subsize_width/Full_size(10)
if min energy for full size = 18 j and obtainable size be 5 mm so 18× (5/10) =18×0.5=9 j ???
Why cannot use Code UG-28(f) for vessel under external pressure greater than 15 psi ? it is depend on temperature Or material impacy testing ... another question is there temp l8mitation for 15psi and where can i find it in Asme section viii ?
WITH D/T=69.7 , L/D 50
in tabular values figur G section ii
60 80
0.306 0.172
Factor A General interpolation =0.24101-03
Factor A with exp(use ln in linear interpolation ) = 0.2267-03
Now which ones to be used ?
i found following from searching here :
Example for first row (natural logs):
Do/T = 500, (log=6.2146), L/Do = 0.231 (log=-1.46534):
log(A) = -0.4385-(-1.46534+1.60944)/(-0.91629+1.60944)*(-0.4385+1.19733) = -0.59625
This would give (excluding the factor 10^-3) A=exp(-0.59625)=0.551 , quite...
Hi
i could not extract factor A from tabluar values figure G
Material from table HA-1
D/T=69.7
L/D=50
1-A=?
2- if there is not same D/L according to L/D how shall be do , forexample in above there are 50 in L/D 60 and also 80
Ex: D/t=20 , L/D=40 A=0.275-02
D/t=22 , L/D=40 Whats A ...
hi
ucs-66(b)(3) describes if the material no need pwht but pwht done for it can reduction 17C ? or if pwht not requirement of this code (asme viii ) but the material required pwht by b31.3 (20mm) and this material repostweld can use 17c reduction ?
which ones are true?
hi , again
1-if the material thickness is 0.875 inch at same temperature also impact testing required? ( As per note ucs-66 A516 G70 N falls in curve D )
2-governing thickness means plate thk with welded or non-welded attachment on plate such reinfircing pad or support thk+ throat × 0.707 ?
hi
following material needs impact testing in pqr ? if yes what is examination temperature
BPV
Material : A516-70N
thk=10mm
temp : -40C
(f) Impact testing per UG-84 is not mandatory for pres-
sure vessel materials that satisfy all of the following:
(1) The material shall be limited to...