  1. wenchop

    Has Hexagon finally deleted coade forum?

    I hope this is not the case, what a loss. [sadeyes]
  2. wenchop

    Has the original COADE forums website (forums.coade.com) been officially shut down?

    I hope this is not the case, what a loss. [sadeyes]
  3. wenchop

    Forums.coade.com

    hello, the site forums.coade.com seems to be down or offline starting a few days ago? Please advise.
  4. wenchop

    Structural Engineering Software

    In Canada, do the provinces regulate which software products may be used in the design/engineering of structures?
  5. wenchop

    Looking for the "bible" of piping stress engineering

    Hi, I am looking for the best book/article/handbook/website/etc. that is the best resource for piping stress engineering. Any comments appreciated. regards,
  6. wenchop

    using a natural gas screw compressor for air compression

    there would be an air dryer process upstream to drop the dew point.
  7. wenchop

    using a natural gas screw compressor for air compression

    hi, is it technically feasible to use a natural gas screw compressor (200 hp or 100 hp electric drive) for air compression? I will appreciate the help! thank you!
  8. wenchop

    applicable code for utility piping in Canada

    thank you gwalkerb. It would be a commercial facility.
  9. wenchop

    applicable code for utility piping in Canada

    hello, what is the applicable code to design of small diameter (3 inch) and short length (few hundred meters) piping with utility (fuel) natural gas and instrument air, in Canada? What does it depend on? thanks for any input.
  10. wenchop

    flare header purge

    At the flare tip, it is clear what purge rates to use, depending on the seal if it is velocity seal or molecular seal or just a utility flare. However, if there are a number of headers and subheaders in the relief system, each has to be purged, both at intermittent rates (e.g. during startup to...
  11. wenchop

    Multiple flares and thermal radiation

    Yes all go at the same time. The duration would be more than a few minutes. If I want to find the minimum height for the flares, the assumption of adding the radiations may not be the best assumption (too conservative). It seems to me that the presence of a flare nearby will pull the flames...
  12. wenchop

    Multiple flares and thermal radiation

    API 521 states: "The impact of multiple flares in proximity operating simultaneously needs to be considered when evaluating thermal radiation." What we have is a case of several flare stacks/risers in parallel in close proximity, so they are almost in the same location. The question is whether...
  13. wenchop

    Pipeline underground or aboveground

    Biginch: I am a chemical engineer, not a mechanical engineer, doing some research, not any type or phase of design. In my projects we have installed Ethafoam successfully to manage expansion of pipelines with changes in temperature, this designed by certified stress engineers. Ethafoam is...
  14. wenchop

    Pipeline underground or aboveground

    Littleinch Thanks for the input, we have not decided on anything yet, just looking at feasibility. Regards,
  15. wenchop

    Pipeline underground or aboveground

    I do not think so, irony and sarcasm do not belong in any serious forum, as by nature they are potentially confusing and in some cases be also passive-agressive.
  16. wenchop

    Pipeline underground or aboveground

    I do not think that irony is a way to make a point in this kind of forum. Anyway, Ethafoam is a product that may help in some situations to help deal with pipeline expansions, not all of them.
  17. wenchop

    Pipeline underground or aboveground

    There is also the Ethafoam product from Dow.... http://www.qualityfoam.com/docs/ethafoam-220.pdf
  18. wenchop

    Pipeline underground or aboveground

    This is a field pipeline, 15 km, in the tropics.
  19. wenchop

    Turndown ratio of separator vessels

    zdas04 Thank you, that is a good point.
  20. wenchop

    Turndown ratio of separator vessels

    Am I correct to suppose that the turndown ratio (capacity utilization) of 1. A two phase separator vessel 2. An three phase separator vessel is from 0-100%? In other words, they can operate at minimum capacity from 0 to 100% with no technical issues. This is about the vessel, I know that the...