  1. Tuga29

    Pipeline Pressure Restfill

    In this case it’s not a multi product pipeline. But my question was raised because operator is using a restfill pressure close to product maximum vapour pressure or even lower. They don’t take care of the pressure.
  2. Tuga29

    Pipeline Pressure Restfill

    So, how was that off-spec crap formed?
  3. Tuga29

    Pipeline Pressure Restfill

    Yes, shut in, we call it resfilling pressure. Concern is that pressure being low, leads to the creation of vapor pockets that will collapse creating erosion on the pipeline wall.
  4. Tuga29

    Pipeline Pressure Restfill

    Hi all. This is not my area and that's why I request your help. In a oil product pipeline what should be the restfill pressure? The restfill is done with the product that specific pipeline transports (ULP, ADO, HFO or JET). My concern is regarding some grade of corrosion prevention. If there...
  5. Tuga29

    Instrument Air Piping Testing

    The maximum operation pressure, given by the Design team, is 1000kPa.
  6. Tuga29

    Instrument Air Piping Testing

    The big issue that we are dealing is that the manufacturer is having leaks. They ddin't tell us yet the gravity, but it doesn't seam good. That's why I would like to know and asked about an acceptance criteria. They asked us if they could only do a service test... it seams they don't have leaks...
  7. Tuga29

    Instrument Air Piping Testing

    Yes, the Code is B31.3. That service test at normal operation pressure possibility is only for Category D fluid service right? Our Design Pressure is 1300kPa. I don't trust these construction guys to use water testing in these instrument lines.
  8. Tuga29

    Instrument Air Piping Testing

    Hi. We are building a new tank farm and we are having now some problems with our Instrument Air lines testing. They were designed to be threaded and pneumatic tested. The issue is that the construction company is having problems with the criteria of zero leaks during the test (1.1 the Design...
  9. Tuga29

    Piping Systems testing. It's not th

    Thank you for all your answers. It's clear for me now.
  10. Tuga29

    Piping Systems testing. It's not th

    Piping Systems testing. It's not the best practice, especially with ball and gate valves, but there is any standard that doesn't allow to pressure test against valves? ASME B31.3 345.3.4 seams to allow that. Can you please give me some points of view regarding this?
  11. Tuga29

    Tank Identification

    I'm only asking about Tag Numbers for Storage Tanks. Tanks are already done, all of them supervised by the "newbie". [dazed]
  12. Tuga29

    Tank Identification

    I would like to ask if there is any regulation/guideline, regarding the Identification of Storage Tanks (API 650). This in terms of size, style and format of lettering. Also regarding colour and location. Can I find this information/guideline or it's ALL Owner definition. Thanks.
  13. Tuga29

    Figure 8 Blanks

    We are in a C5-M corrosive environment and the design define just figure 8 blank. In normal production the blind face will corrode fast.
  14. Tuga29

    Figure 8 Blanks

    Could you please give some advice on Figure 8 Blanks CS protective coating. Is there any requirement. Contractor says it can't be painted and we don't agree with that.
  15. Tuga29

    Pipeline Warning Tape

    Yes, but the contractor is trying to use just a colored tape (black and yellow) and I wanted to check if there is anything required by a standard. API RP 1109 just mention warning tape as an optional and BS EN 12613 I don't have it.
  16. Tuga29

    Pipeline Warning Tape

    Can anyone please give me information about requirements for warning tapes for underground pipelines (oil products). Namely regarding lettering. Does it needs to have lettering or not.
  17. Tuga29

    Pipeline Welding - Spatter

    WPS specify 90-140A. They were using 120A more or less. The 4.0 rods are specified for 120-180A. It's very strange that they can't do the work with the approved WPS.
  18. Tuga29

    Welder Qualification ASME IX

    For the welding on site we didn't change anything. It´s everything according to the WPS. One of the welders that is doing the root pass was qualified with another WPS, that one with different size rod. But all the essential variables were the same.
  19. Tuga29

    Pipeline Welding - Spatter

    We are just starting. Those were the first welds.
  20. Tuga29

    Welder Qualification ASME IX

    Yes, I think they can. Just the rod thickness changed and that's not an essential variable. Thanks.