Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. GasOilEng

    Fired Heater

    Dear All. Thanks for your reply, I asked the vendor and I am waiting for response. Regards
  2. GasOilEng

    Fired Heater

    Dear All, While reading Mechanical Datasheet of existing Fired Heater package, We found that vendor/Manufacturer has taken ambient temperature 25C for Stack design and 50C for the rest of fired heater to design. Please could someone explain to me what was the reason for these two different...
  3. GasOilEng

    2" SCH40 line of oily water

    Hi Thanks for this thoughts which are valuable for me. Especially Mr georgeverghese , your thoughts make things clearer. What I think is that there is gas blowby from the reg KO drum when there is LT failure, this may cause knocking and hammering , hence line deformation. Because we notice...
  4. GasOilEng

    2" SCH40 line of oily water

    Hi everybody Thanks everybody for your technical approaches, but still give you more details for the damaged 2" line oily water in order to give more explanation of that phenomenon. LV's and SDV valves are for level control of these drums. Best regards...
  5. GasOilEng

    2" SCH40 line of oily water

    Hi everyboy I am process engineer in LPG plant. The oily water generated from regeneration phase of MolSiev bed of natural gas is sent from regeneration drum working @ 90bar & 50 to 60°C to API oily water treatement unit (Working pressure 1bar, ambient temp) passing by control valve through 2"...
  6. GasOilEng

    Slug of Condensate

    Hi LittleInch Firstly,I want to know basing on those flows of liquids, How can I estimate the slug volume. Secondly, the size of Slugcatcher that I want to have is L<10m, D<3m. Thanks
  7. GasOilEng

    Slug of Condensate

    Hi everybody! Mr Georgeverghese; If I got you, the 130m3 per hour arrives during 05 hours minimum, Not 130m3 over 05 hours. Many thanks for you George & LittleInch
  8. GasOilEng

    Slug of Condensate

    Hi We have pipeline transporting Gas with MW of 24 to 25g/mol along the 130km, to LPG facility. Every three day, the CPF sending the gas to LPG plant, perform pigging operation. As the result, LPG plant receives a big quantity of cendensates about 130m3/h over 5 to 8hours.Please, I would like...
  9. GasOilEng

    Hi! I want to have an explanation

    Hi I entirely agree with you about CO (incomplete reaction of oxidation, but what about H2S.Is is possible that O2 reacts w/ sufides in normal conditions 1atm. and 30 - 35°C to produce H2S. If it is possible, I think it would be the SO2 as product not H2S.
  10. GasOilEng

    Hi! I want to have an explanation

    Hi Don1980, (sufide an inorganic anion of sulfur with the chemical formula S2− or a compound containing one or more S2− ions) Is is possible that O2 reacts w/ sufides in normal conditions 1atm. and 30 - 35°C to produce H2S. If it is possible, I think it would be the SO2 as product not H2S.
  11. GasOilEng

    Hi! I want to have an explanation

    Hi Don1980 Many thanks for your brief explanation ,sounds that's H2S doesn't previously exist in the process gas, it is the product of chemical reaction of O2 with sulfides adsorbed on Mosiev.
  12. GasOilEng

    Hi I am simukating in dynamic m

    Hi I am simukating in dynamic mode, but it doen't converge when simulating COMPONENT SPLITTERS in dynamics, has anyone a piece f information how to solve it
  13. GasOilEng

    Hi! I want to have an explanation

    Hi don1980, thanks for your replying We have followed UOP instructions for change out, but what I want , is possible scientific explanation of what happened. Thanks
  14. GasOilEng

    Hi! I want to have an explanation

    Hi! I want to have an explanation for this phenomenon happened recently in our LPG dehydration section; We are using UOP94 and UOP945 Mol Sieve A4. While trying to empty dryer vessel for changing a new UOP Mol sieve we had checked the the gases outlet from the dryer with Gas Tester before...
  15. GasOilEng

    Flare Design

    Hi You can get by using Aspen flare Analyzer
  16. GasOilEng

    Oil Gas Separator PCV - Fail Open or Closed?

    Hi I'd like to know which kind of PCV valve to flare should we install to oil gas separator, ie, Fail to Open or Fail to close. Thanks in davance
  17. GasOilEng

    Suction pressure of centrifugal compressor to be lowered

    Hi EmmanuelTop We are not going to change compression ratio, but theoretically what about flow, I mean, sizing : suction line, impellers of compressor and so on. Many thanks for your replying
  18. GasOilEng

    Suction pressure of centrifugal compressor to be lowered

    Hi We have centrifugal compressor of 8.0barg suction pressure (15.0barg discharge pressure), we want to change its suction pressure to 5.0barg (New operating pressure), What are the guidlines to follow in order to know if it's possible or no? please give me help. Many Thanks
  19. GasOilEng

    Heat recovery system to designed

    Hi; I want to know how to design a heat recovery system from gas exhaust from gas turbine in order to heat oil of hot oil system. Please can anyone help me for this. Thank you
  20. GasOilEng

    check valve (FSV) as safety device in API 14C

    Hi I want to design a heat recovery system from Exhaust gas of gas turbine ,to heat up oil of hot oil system. can anyone give tips to how size the heat exchanger to be used. Many thanks in advance for any help.

Part and Inventory Search