Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Hamza1988

    Error occurred while starting the solver module.

    Hi, I am trying to solve a static structural problem in Ansys 17 but it gives me the error "An error occurred while starting the solver module. Please refer to troubleshooting section in Ansys mechanical user guide". I've checked all the possibilities in the mechanical user guide but nothing...
  2. Hamza1988

    Bush and sleeve clearances in vertical pumps

    Hi everyone, we have a vertical pump (VS4 type) which has multiple bush bearings. During a previous overhaul, all bushes were renewed but when the pump was installed back, high vibration was recorded due to high bush clearances. Can anyone help me and provide me with a standard that mentions the...
  3. Hamza1988

    MSc in advanced mechanical engineering: Loughborough vs Imperial College London

    Apologies for the 'in london' part. What I wanted to write was 'in the UK'. So if I look at the rankings Imperial is probably in the top 10 in the world while loughborough barely makes it in the top 100. But I really want to know which university is actual better in academic terms not just by...
  4. Hamza1988

    MSc in advanced mechanical engineering: Loughborough vs Imperial College London

    Hi guys, I am looking to do my postgraduate at a good University in London and I am not a resident there therefore I am not sure about the reputation of the universities when it comes to Mechanical Engineering. I have done some research and I have shortlisted two Universities to do my MSc in...
  5. Hamza1988

    Suction pressure less than vapor pressure

    Hi guys, we are looking to buy a new horizontal overhung centrifugal pump and one of the suppliers have sent us the datasheet of a pump which puts the suction pressure at 0.30 barg, maximum suction pressure at 0.8 barg, and the vapor pressure of the liquid at 0.6 barg. Now we know that if the...
  6. Hamza1988

    VS4 pump having high vibration possibly due to wrong bush clearances

    Thanks guys, The coupling is a jaw coupling. The pump was initially overhauled due to the same reason, high vibrations. When our vibration analyst performed the analysis, he found high bush clearances to be the reason. We removed the pump and replaced the bushings with new ones as a lot of...
  7. Hamza1988

    VS4 pump having high vibration possibly due to wrong bush clearances

    Hi, a VS4 type vertical pump is having high vibration though the pump was recently overhauled. The pump bushes were replaced during the overhaul and the sleeve-bush clearance was 0.28 mm. The issue was that the pump manufacturer did not provide any design range for the bush clearances therefore...
  8. Hamza1988

    Shaft run-out check

    Hi guys, During the run-out check of a pump shaft, how important is it to make sure that the two V-blocks are vertically at the same level. In other words, the shaft being check for run-out is perfectly horizontal. Thanks.
  9. Hamza1988

    Actuator not functioning after hydraulic oil replacement

    Thanks guys, the problem is still there. You guys suggest that there might be air trapped in the system. We do have a bleed valve in the hydraulic circuit which we have used to bleed the air out. Plus if air is trapped in the system, what usually happens is that the pressure in the hydraulic...
  10. Hamza1988

    Actuator not functioning after hydraulic oil replacement

    Hi, we have large actuators to control the operation of 20 inch butterfly valves. These valves are discharge valves of large vertical pumps. So recently we had to replace the oil (around 150 liters) of the control unit of the actuator. After replacement of the oil, the valve funcionality was...
  11. Hamza1988

    Hi, quite recently I saw a plunger

    Hi, quite recently I saw a plunger type positive displacement pump which had a strange plug at the bottom of the casing. The plig seemed to be slighlty leaking while running. When I removed the plug l, I found that it is not a plug but a sintered bronze air filter. This air filter was on the...
  12. Hamza1988

    Formula one car body and wings temperature at high speed

    What about the front wing and the rear wing where the pressure on the top of the wing increases due to its profile as air passes over it at high speed. Shouldn't the increase in pressure cause the air temperature to increase which eventually should increase the temperature of the wing?
  13. Hamza1988

    Formula one car body and wings temperature at high speed

    Hi everyone!! I was wondering during a formula one race, does the temperature of the formula one car skin (body and wings) increase due to its moving at high speed??
  14. Hamza1988

    Hi, I am a mechanical engineer and

    Thanks, but the rankings that you've showed seem to be for computer science major. Is there a similar list for "computational science and engineering"? or should a list for applied mathematics or mechanical engineering be relevant?
  15. Hamza1988

    Hi, I am a mechanical engineer and

    Yes ofcourse...I currently live in dubai and am willing to relocate.
  16. Hamza1988

    Hi, I am a mechanical engineer and

    Hi, I am a mechanical engineer and have been working in the maintenance sector for about 3 years now. Now, I am thinking of changing my career path and going for an MSc or MEng in computational science and engineering. I have always loved working with different software packages and solving...
  17. Hamza1988

    Oil breather blockage and oil leakage through the seal

    Thank you electricpete and JJpellin. I am going to try and clean the breather on one of the pumps next week and see if this stops the leakage through the seal.
  18. Hamza1988

    Oil breather blockage and oil leakage through the seal

    Thank you electricpete. Yes the system is a constant oil leveler based and every time we run the pump, the whole oiler empties out within 3 to 4 hours. What I understand is that the pressure above the oil level inside the pump bearing housing increases with time and increase in temperature as...
  19. Hamza1988

    Oil breather blockage and oil leakage through the seal

    Hi, lately, we at our company are having quite a lot of oil leakages in centrifugal pumps with deflector seals. Someone suggested that the reason of oil leakage through a deflector type seal or a bearing isolator could be a blocked oil breather. Is this true and how would a blocked breather on a...
  20. Hamza1988

    Sleeve bearing lube oil turned black

    Thank you guys, Spot on Johnny Pellin, the arrangement we have perfectly matches the description you have provided except that we do have a cooling water jacket. I forgot to mention about the oil level which was quite high. After draining about 4 liters of oil, the level could be seen through...

Part and Inventory Search