Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. mcc202

    Welds at Beam Bearing Plates

    When beams bear on CMU or Concrete walls, I have always shown the beam field welded to the bearing plate, with the bearing plate set in the wall with anchor rods. Recently I have ran into issues where the walls have cracked at the bearing pockets just below the bearing plate, most typically at...
  2. mcc202

    Steel Beam Bearing Pockets and Thermal Expansion

    Hi There, I was wondering if anyone had any insight into how to allow for thermal expansion/contraction of structural steel beams bearing on CMU or Concrete walls. I've had some issues with cracking at the bearing pocket where the beam has engaged the bearing plate as it expands/contracts and...
  3. mcc202

    Tedds Alternative

    Thanks everyone, I was not expecting this many responses. We are going to stick with Tedds for the time being and devote some time into trying to learn the programs capabilities a bit more. Clear Calcs seems promising but I think needs some more time to develop, we will revisit that in a year...
  4. mcc202

    Tedds Alternative

    We are building engineers with an office of about 50. Looking for a program similar to Tedds or Enercalc that does individual excel-like calculations, like calculating wind loads, baseplate design, footing design, retaining wall design, etc. Thanks
  5. mcc202

    Tedds Alternative

    We currently use Tedds and I hate it. It's super clunky and is very limited in what it is able to do. Are there any viable alternative to Tedds? The only other alternative that I have used is EnerCalc which isn't much better and actually may be worse? Just curious what other programs other...
  6. mcc202

    0.5% Reinforcement in Existing Concrete Columns

    From what I can tell, it does appear to have the same effect for purely axial strength calculations and it is actually what SP Column says they do in their program: "By default Architectural option is selected for which the capacity of the section is reduced. For the ACI codes, the reduction...
  7. mcc202

    0.5% Reinforcement in Existing Concrete Columns

    I proportioned f'c down based on the actual reinforcement ratio from 1%...so for 0.5%, you get half the f'c. I believe that has the same effect as reducing the effective area proportionally. This is also the method in which SP Column calculates "Architectural" column strength based on their...
  8. mcc202

    0.5% Reinforcement in Existing Concrete Columns

    Yes, I am currently analyzing using these provisions for the reduction of strength. It just seems a little odd that if you keep the same size rebar and increase the column size, there's the potential to get less strength because the percentage of steel decreases, even though the column size...
  9. mcc202

    0.5% Reinforcement in Existing Concrete Columns

    Hello, I am analyzing an early 1900s existing concrete structure for a potential overbuild. Based on a field investigation, the columns appear to have been reinforced with about 0.5% vertical steel. Per ACI 318-14 section 10.3.1.2, you would reduce your concrete strength proportionally to...
  10. mcc202

    End Moment Magnification in SP Column

    Thanks everyone. Does anyone have a copy of Richard Furlong's paper? I have now seen that document referenced in several threads...seems worth a read.
  11. mcc202

    End Moment Magnification in SP Column

    Yes...in a round about way. ACI references 6.6.4.5 for the calculation of member length slenderness effects, which is the Non-Sway Moment Magnification Method. I suppose I could then run SP Column as Non-Sway with the 2nd order moments input from our Ram 2nd Order Analysis. That's what I was...
  12. mcc202

    End Moment Magnification in SP Column

    It is my understanding of ACI that when analyzing concrete columns subject to sway that the end moments obtained from a second order analysis may be utilized in lieu of magnifying the end moments, but we would still be obligated to check moment magnification along the member length. Is there a...
  13. mcc202

    ETABS Enveloped Base Reactions

    Thanks! I am getting the impression that most engineers use excel to determine the base reactions. I am accustomed to using RAM SS where most of that output is readily accessible within the program. Another interesting item is that ETABS will not calculate a gust factor when determining wind...
  14. mcc202

    ETABS Enveloped Base Reactions

    Hello, I am curious how other engineers are obtaining base reaction output for foundation designs. As far as I can tell, ETABS will not provide you with an enveloped base reaction and only considers live load reduction in the design phase. What I have done is isolated my joints at the base...
  15. mcc202

    Enveloped Base Reactions and Live Load Reduction

    Hello, I am curious how other engineers are obtaining base reaction output for foundation designs. As far as I can tell, ETABS will not provide you with an enveloped base reaction and only considers live load reduction in the design phase. What I have done is isolated my joints at the base...
  16. mcc202

    A307 Bolts - Strength Reduction Based on Grip Length

    Thanks. It appears that this footnote was removed for tensile stress in the 14th edition. Here is the explanation I received from AISC: "The footnote you mention only applies to the shear strength of A307 bolts. The reason for this reduction is explained in the Commentary to Section J3.6 of...
  17. mcc202

    A307 Bolts - Strength Reduction Based on Grip Length

    AISC Steel Construction Manual Table J3.2 specifies that the nominal tensile stress and nominal shear stress shall be reduced for A307 bolts based on the grip length of the bolt in the connection. This is specified in footnote [b] in this table. Why is this? This reduction gets very...
  18. mcc202

    Pile Buck (SPW 911) Soldier Pile Example

    How do I model soldier piles using SPW 911? We have an article on this subject; Please contact us for a downloadable PDF. This is what Pile Buck's website says, however it is my understanding they are out of business. Does anyone have this pdf?
  19. mcc202

    Ram Elements Version 11 - Unbraced Lengths

    Version 11 of Elements revised how unbraced lengths (Lb, L33, L22) were input. The sum of unbraced lengths must now match the totla length of the segment. This is very frustrating to me and it makes it very difficult for modeling. Has anyone had any similar issues with this? What are the...
  20. mcc202

    Metal Deck Diaphragms with Openings

    Does anyone know of a good design example for a designing roof deck diaphragms with openings?? I have an existing building where we are removing a portion of the deck for an addition. I am having issues resolving the chord forces (I am OK for shear) around the opening and was wondering if...