  1. mkees

    4160VAC Sync Motor and Physics

    Thanks everyone, for your help I will try all the suggestions. This has been a learning experience as I hoped it would be. Watch in the future I will keep you posted when I find the result.
  2. mkees

    4160VAC Sync Motor and Physics

    There is a new rotating assembly, and the slip frequency is lower. I spoke to the manufacturer to see if the is an adjustment for the slip frequency, there's not. The question remains do I need to reduce the pressure in the compressors? Do you all think just adjusting the field current may be...
  3. mkees

    4160VAC Sync Motor and Physics

    Electricpete you are correct about the connecting rod. Waross, please realize, I am a instrumentation and controls guy, I studied motors and wrote a final paper about them for my degree years ago. What I've seen since has been 480 3 phase with a VFD. So please don't assume that I'm using the...
  4. mkees

    4160VAC Sync Motor and Physics

    Let me start with the easy question first, there is no tach, the exciter field is applied as soon as the motor contactor is energized. Exciter field current is constant at about 6.5 amps for 30 seconds, then for 5-1/2 minutes the exciter field is held constant at 13 amps while the bypass valve...
  5. mkees

    4160VAC Sync Motor and Physics

    I do apologize, these are brushless motors. I know that when the motor is started the exciter field current is applied, i don't know if there is a contact providing this to the 469, I"ll have to look at the prints on Monday. I also know there is a time (30 seconds) before the 469 really...
  6. mkees

    4160VAC Sync Motor and Physics

    Here's what I have, a Basler MVC236, a Basler SCP250m, and a Hyundai Ideal Digital Synchronizer System. The motor always starts and spins, but doesn't always sync, at that point I get a PF trip on my Multilin 469. I went back and read the book on the Hyundai Ideal DSS, and sure enough it works...
  7. mkees

    4160VAC Sync Motor and Physics

    Waross, yes it is a new sync controller. I know it is different from the old because I had to pull wires from the CT's and PT's to connect to the controller. I thought the controllers were Power Factor based and not frequency. I don't know of anything on these controllers that controls...
  8. mkees

    4160VAC Sync Motor and Physics

    Better description of this compressor. This compressor compresses on both strokes, pressure on both sides. This is a natural gas compressor (Cooper). The crankcase is not pressurized. I have recently upgraded the sync controller, because the original, was nearly prehistoric, parts were...
  9. mkees

    4160VAC Sync Motor and Physics

    I have 2 4160VAC 4500hp Sync motors that power reciprocating compressors. My issue is starting the electric motors, this is very inconsistent sometimes they start and sync, and sometimes they don't sync. I am trying to make the issue with management that the reason they are inconsistent is...
  10. mkees

    Communication or Application

    Thanks for the information, I did cycle power on both the plc and the hmi, but no help. The manufacturer did finally call back and found that a DCE application was locked, they stopped and restarted it. One would think that if you reboot the computer the hmi is running on that that application...
  11. mkees

    Communication or Application

    I am working on an emissions monitoring system (Manufactured by Systems Monitoring). We had a thunder storm come through the area and is the possible blame for my problem. The NOx analyzer had to be sent out for repair, no big deal. But with the rental unit installed I tried to perform a...
  12. mkees

    Utility and generator operation confussion

    Thanks for the advise, I will check the the phase rotation at the same point. The utility phase rotation is CBA, I will check what I write more closely next time. Waross, saying the obvious things are not offensive, I often need reminded of the obvious. Unfortunatly, I am the last call when the...
  13. mkees

    Utility and generator operation confussion

    Motors are 3 phase induction motors, phase to neutral voltage is 284 on all 3 legs, please ask more questions so I can get this fixed. this customer is getting very upset.
  14. mkees

    Utility and generator operation confussion

    I want to the job site today, the motors ar 480 3 phase. again I checked the phase rotation of the utility which was CCW, the the generator which was CW. Voltage at the generator was about 485 and the freq was 60.4. We couldn't transfer, the facility wouldn't let us. I conducted a test with an...
  15. mkees

    Utility and generator operation confussion

    I will check the freq., The firld tech assures me it is correct (60HZ), if it is correct does anyone have any other ideas?
  16. mkees

    Utility and generator operation confussion

    I am having a problem with a facility, that uses a generator as a back-up power source. When this facility is running on utility all is normal, when they switch to generator all the motors go to half speed. This is a 480 VAC 3 phase system. We have chacked the voltage when generator is running...
  17. mkees

    Generator Monitoring

    Yes, it is a Diesel. When I arrived at the site the engine was running and sharing the load (Parallel operation) I will check the governor.
  18. mkees

    Generator Monitoring

    If this forum will recall, several weeks ago I posted, requesting advice for some 13.2KV generators that had burned up, and associated testing and monitoring. I have been monitoring, and performing test, and have not seen anything that looks out of the ordinary. Please remember I am new to power...
  19. mkees

    Maybe somebody could help me with SR4B generator?

    If I recall, you may be able to check the main rotor at the rotating rectifiers. Disconnect the output side of the rectifiers and I think that is the input to the main rotor windings. There is also a proceedure to check the the rotating rectifier assembly, did you perform that proceedure? Do you...
  20. mkees

    UL Listing

    Thanks, that's kind of what I thought.