  1. irulandi

    engineers in different jobs

    What is the different between contractor engineer vs consultant engineer vs clients engineer. pls explore.
  2. irulandi

    Batching Plant concrete Yield

    Dear Friends, I am having Cement wastage more at my Project in Batching Plant Concrete. I Cheked Calibration and Dial Gauge movement in batching Plant, Everything is good. But when i am taking Yield from Batching Plant i found 7% of Required Output is less. What are the possibilities to avoid...
  3. irulandi

    any alternative method of sand blasting work

    dear Ron. please explore the methodolgy of dry ice sand blasting works. if possible give the rate analysis of per Mt.
  4. irulandi

    any alternative method of sand blasting work

    dear friends any body is having any alternative method of sand blasting works in structural steels. pls explore
  5. irulandi

    cracks in Masonary walls

    dear again irulandi now the cracks is enlarging , specifically its come staircase waist slab and near stair cases area. i checked block the compressive strength test also passed. now what i do . please throw some light on this
  6. irulandi

    Sand Blasting in Monsoon time - Reg

    Dear Friends , i am constracting one town plaza structure in hill station at mumbai. It is Double storied structure one floor is concrete top floor is truss & sheeting. Column is steel column from foundation. For this project my sand blasting in structurl steel activity start in Heavy Monsoon...
  7. irulandi

    cracks in Masonary walls

    i am constructing one hospital project at mumbai. In Masonary works we have used solid blocks, yesterdat i found in one wall is cracked in 5m lenght and width is 5to6mm. That wall construction was over by before two months ( inculding plastering ) now POP applying activity in progress. I found...
  8. irulandi

    cracks in RCC Slabs

    i have constructing one hospital 11 storied building at mumbai. i am facing cracks problems at concrete in every pouring after five hours the concrete surface is showing cracks ( specifically in slabs ) Width of cracks maximum 6MM Depth of cracks 20 to 30MM The thickness of RCC slab is 150MM...