Yes, I am familiar with the dog leg approach in fact we have submitted a design with it, where the magmeter was designed to flow full pipe through the dog leg after a sediment tank and the Authority’s Engineer would not approve it saying that it will get clogged due to sediment (the processing...
Yes, but all manufacturers hype-up their products just ask any of them and they will tell you their product is the best on the market and it will do whatever you asked for...anyway everything I read on magmeters for partial flow shows accuracy of 3% to 5% of the actual flow rate, the processing...
I am trying to convince a local sewer authority to allow my client to utilize an electromagnetic flowmeter for partially full pipe specifically a Parti-Mag II for process wastewater (vegetable washwater). The Authority uses magmeters but only on sewer mains that are constantly full. Their...
I am trying to convince a local sewer authority to allow my client to utilize an electromagnetic flowmeter for partially full pipe specifically a Parti-Mag II for process wastewater (vegetable washwater). The Authority uses magmeters but only on sewer mains that are constantly full. Their...