Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. faroquex

    SAP2000 - Shell one way load distribution

    I think this is the limitations of Etabs if membrane is supported on Wall one way load distribution is not possible. So silly.
  2. faroquex

    SAP2000 - Shell one way load distribution

    I think this is the limitations of Etabs if membrane is supported on Wall one way load distribution is not possible. So silly.
  3. faroquex

    SAP2000 - Shell one way load distribution

    Thanks johnbridge231. I defined slab as a membrane (with modifier m11=.00001) and walls as a shell. But I found All walls carry the equal load. Please refer to the attachment. http://files.engineering.com/getfile.aspx?folder=399eafc9-8b4b-401c-86fb-62713d72a953&file=YY.s2k
  4. faroquex

    Modelling Moment and/or Shear Releases in Shell Elements?

    Select the node/nodes you want to release. Disconnect it and connect them by weld constraints.
  5. faroquex

    SAP2000 - Shell one way load distribution

    Hello I need to model a wall/roof system. My simplified model consists of 4 ways (box in plan) and at roof one way slab. This mean only two slabs will carry the vertical load imposed on the slab. To do so, I disconnected all nodes between slab and walls and connect corresponding wall and slab...